flowserve.com

4.6.6.4 Piping connection - bearing housing

cooling system

Make connections as shown below. Liquid at less

than 32 °C (90 °F) should be supplied at a regulated

flow rate of at least 0.06 l/s (1 US gpm).

Figure 4-25

4.6.6.5 Piping connection - support leg cooling

for centerline mounting option

If the casing is centerline mounted, and the process

temperature is over 178 °C (350 °F), then the casing

support legs may need to be cooled. Cool water - less

than 32 °C (90 °F) - should be run through the legs at a

flow rate of at least 0.06 l/s (1 US gpm) as shown below.

Figure 4-26

4.6.6.6 Piping connection - heating/cooling fluid

for jacketed cover/casing

The piping connections for jacketed covers and

casings are shown below. The flow rate of the

cooling water - less than 32 °C (90 °F) - should be at

least 0.13 l/s (2 US gpm).

Figure 4-27

Figure 4-28

Notes:

1. When circulating steam, use top hole for inlet. Both bottom

holes must be plumbed together for outlet, to ensure draining

both sides of jacket.

2. When circulating liquid use both bottom holes as inlets. Use top

hole as outlet.

4.6.6.7 Piping connection - Oil mist lubrication

system

The piping connections for an oil mist lubrication

system are shown below.

Figure 4-29

Figure 4-30

4.7 Electrical connections

Electrical connections must be made by

a qualified Electrician in accordance with relevant

local national and international regulations.

It is important to be aware of the EUROPEAN

DIRECTIVE on potentially explosive areas where

compliance with IEC60079-14 is an additional

requirement for making electrical connections.

It is important to be aware of the EUROPEAN

DIRECTIVE on electromagnetic compatibility when

wiring up and installing equipment on site.

Attention must be paid to ensure that the techniques

used during wiring/installation do not increase

electromagnetic emissions or decrease the

electromagnetic immunity of the equipment, wiring or

any connected devices. If in any doubt contact

Flowserve for advice.