UNIREX Pump User Manual

Page 35

Advertising
background image

MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06

Page 35 of 68

flowserve.com

5.2.2 Grease

5.2.2.1 Regreasable

Single shielded regreasable bearings

When the grease lubrication option is specified,

single shielded bearings, grease fittings and vent pipe

plugs are installed inboard and outboard.

The orientation of the bearing shields

is different for horizontal pumps (Standard,

Sealmatic, Unitized, Recessed, and Lo-Flo - see

figure 5-7) and In-Line pumps (see figure 5-8).

Figure 5-7: Horizontal pump shield orientation

Figure 5-8: In-Line pump shield orientation

Horizontal pump bearings are packed with Exxon

POLYREX EM grease prior to assembly. For

relubrication, a grease with the same type base

(polyurea) and oil (mineral) should be used. In the

case of the In-Line pump the bearings are packed

with Exxon Unirex N3 grease. For relubrication, a

grease with the same type base (lithium) and oil

(mineral) should be used. To regrease, remove the

pipe plug from both the inboard and outboard bearing

location. (See figure 5-9.) After relubricating the

bearings three times, it is typically recommended that

the bearing housing is cleaned out.

To regrease bearings under coupling

guard, stop pump, lock the motor, remove coupling

guard, and then regrease the bearings.

The amount of grease required for horizontal pumps

is shown in figure 5-10 and for In-Line pumps in

figure 5-11.

Figure 5-9: Regreasable configuration

Figure 5-10: Horizontal lubrication amounts

Housing

Initial lube

Relubrication

Group 1 inboard

Until grease

comes out of plug

7.5 cm

3

(0.46 in.

3

)

Group 1 outboard

Until grease

comes out of plug

14 cm

3

(0.85 in.

3

)

Group 1 duplex

34 cm

3

(2.1 in.

3

)

17 cm

3

(1.0 in.

3

)

Group 2 inboard

Until grease

comes out of plug

17 cm

3

(1.0 in.

3

)

Group 2 outboard

Until grease

comes out of plug

28 cm

3

(1.7 in.

3

)

Group 2 duplex

68 cm

3

(4.1 in.

3

)

34 cm

3

(2.1 in.

3

)

Group 3 inboard

Until grease

comes out of plug

30 cm

3

(1.8 in.

3

)

Group 3 outboard

Until grease

comes out of plug

54 cm

3

(3.3 in.

3

)

Group 3 duplex

115 cm

3

(7.0 in.

3

)

60 cm

3

(3.7 in.

3

)

Figure 5-11: In-Line lubrication amounts

Housing location

New bearing

Relubrication

Group 1 inboard

10 cm

3

(0.6 in.

3

)

7.5 cm

3

(0.46 in.

3

)

Group 1 outboard

20.5 cm

3

(1.3 in.

3

)

14 cm

3

(0.85 in.

3

)

Group 2 inboard

16.4 cm

3

(1.0 in.

3

)

17 cm

3

(1.0 in.

3

)

Group 2 outboard

47.4 cm

3

(2.9 in.

3

)

28 cm

3

(1.7 in.

3

)

*If new bearings are not lubricated, they should be packed prior to

installation and the housing lubricated as described above.

Do not fill the housing with oil when

greased bearings are used. The oil will leach the

grease out of the bearings and the life of the bearings

may be drastically reduced.

5.2.2.1 Grease for life

Double shielded or double sealed bearings

These bearings are packed with grease by the

bearing manufacturer and should not be relubricated.

The replacement interval for these bearings is greatly

affected by their operating temperature and speed.

Shielded bearings typically operate cooler.

Advertising