UNIREX Pump User Manual

Page 30

Advertising
background image

MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06

Page 30 of 68

flowserve.com

Figure 4-22: Allowable stand loads

F

T MAX

in N (lbf)

F

N MAX

in N (lbf)

Combination loading in N (lbf)

GP1 pumps

8 020

(1 800)

108 531

(24 400)

F

N

+ (13.556) F

T

✦★✧✪✩✍✫✭✬✍✮☎✧

F

N

+ (13.556) F

T

✦✰✯✓✱✭✱✲✩✍✩

GP2 V-10 pumps

8 129

(1 827)

120 115

(27 004)

F

N

+ (0.0019) F

T

2

- (0.941) F

T

✦★✧✘✯☛✩✳✧✍✧✪✬

F

N

+ (0.0086) F

T

2

- (0.941) F

T

✦✰✯☛✴✭✩✍✩✎✱

GP2 V-13 pumps

6 792

(1 535)

140 461

(31 579)

F

N

+ (0.0018) F

T

2

+ (8.453) F

T

✦✵✧✶✱✲✩✷✱☛✸✚✧

F

N

+ (0.0079) F

T

2

+ (8.453) F

T

✦✰✮☎✧✝✬✍✴✍✹

4.6.5 Pump and shaft alignment check

After connecting the piping, rotate the pump drive

shaft clockwise (viewed from motor end) by hand

several complete revolutions to be sure there is no

binding and that all parts are free. Recheck shaft

alignment (see section 4.5). If piping caused unit to

be out of alignment, correct piping to relieve strain on

the pump.

4.6.6 Auxiliary piping

4.6.6.1 Mechanical seal

When the pump is intended to be equipped with a

mechanical seal, it is Flowserve standard practice to

install the mechanical seal in the pump prior to

shipment. Specific order requirements may specify

that the seal be shipped separately, or none be

supplied. It is the pump installer’s responsibility to

determine if a seal was installed. If a seal was

supplied but not installed, the seal and installation

instructions will be shipped with the pump.

Failure to ensure that a seal is installed

may result in serious leakage of the pumped fluid.

Seal and seal support system must be installed and

operational as specified by the seal manufacturer.

The stuffing box/seal chamber/gland may have ports

that have been temporarily plugged at the factory to

keep out foreign matter. It is the installer’s

responsibility to determine if these plugs should be

removed and external piping connected. Refer to the

seal drawings and or the local Flowserve

representative for the proper connections.

4.6.6.2 Packing

When the pump is intended to be equipped with shaft

packing, it is not Flowserve standard practice to

install the packing in the stuffing box prior to

shipment. The packing is shipped with the pump. It

is the pump installer’s responsibility to install the

packing in the stuffing box.

Failure to ensure that the packing is

installed may result in serious leakage of the pumped

fluid.

4.6.6.3 Piping connection – seal/packing support

system

If the pump has a seal support system

it is mandatory that this system be fully installed and

operational before the pump is started.

If packing is used:

4.6.6.3a Packing lubrication

Water, when compatible with the pumpage, should be

introduced into tap V (figure 4-23) at pressure 69 to

103 kPa (10 to 15 lbf/in.

2

) above the stuffing box

pressure. The gland should be adjusted to give a flow

rate of 20 to 30 drops per minute for clean fluid. For

abrasive applications, the regulated flow rate should

be 0.06 to 0.13 l/s (1 to 2 US gpm).

Figure 4-23

Grease lubrication, when compatible with the liquid

being pumped, may be used. Again, introduced into

tap V.

In non-abrasive applications the liquid being pumped

may be sufficient to lubricate the packing without

need for external lines. Tap V should be plugged.

4.6.6.3b Abrasive packing arrangement

The installation procedures are the same as the standard

packing with some exceptions. A special lip seal is

installed first, followed by two seal cage assemblies, then

two of the packing rings provided (figure 4-24). A flush

line from a clean external source should be connected

via tap V, in the top of the stuffing box.

Figure 4-24