Only one side of the guard needs to be removed. To

reassemble simply reverse the above procedure.

Figure 5-15

The coupling guard shown in figure 5-15 conforms to

the USA standard ASME B15.1,

“Safety standard for

mechanical power transmission apparatus.”

Flowserve manufacturing facilities worldwide conform

to local coupling guard regulations.

5.5.2 ClearGuard™ - optional

Flowserve offers as an option a ClearGuard™, which

allows you to see the condition of the coupling (see

figure 5-16). This guard can be used in place of the

existing clamshell guard described above.

Disassembly of the ClearGuard™ is accomplished by

removing the fasteners that hold the two guard halves

together followed by removing the foot bolts and

rotating the support leg out of the slot on the guard.

Figure 5-16

5.5.3 Trimming instructions

In order to correctly fit the pump/motor configuration,

each guard must be trimmed to a specific length.

This trimming is done on the motor end of the guard.

a) Measure minimum distance from the center of

mounting hole in the baseplate to the motor.

(If clam shell guard proceed to step c.)

b) Locate a reference center in the slot of the

ClearGuard™ coupling guard flange, see figure

5-17. Transfer the length measurement to the

guard using this reference center.

c) Trim the motor end of the guard according to the

above measurement. Trimming is best done with

a band saw, but most other types of manual or

power saws give acceptable results. Care must

be taken to ensure that there is no gap larger

than 6 mm (0.24 in.) between the motor and the

coupling guard.

d)

If motor diameter is smaller than guard

diameter, trim guard so that it extends over the

end of the motor as far as possible.

e) Deburr the trimmed end with a file or a sharp

knife if ClearGuard™. Care must be taken to

eliminate all sharp edges.

Figure 5-17

5.5.4 Assembly instructions

Clam shell guard

a) Mount support leg to each clam shell, figure 5-15.

b) Attach one half of the guard to the baseplate.

c) Engage the tabs of guard halves together.

d) Attach the second support leg to the baseplate.

ClearGuard™

a) Place the bottom and top halves of the guard

around the coupling.

b) Install the support legs by inserting and then

rotating the tab on the leg through the slot in the

guard until it comes through and locks the top

and bottom halves of the guard together.

c) Attach the support legs to the baseplate using the

fasteners and washers provided.

d) Install fasteners in the holes provided to secure

the guard flanges together.

5.6 Priming and auxiliary supplies

The Mark 3 standard, Sealmatic, Recessed Impeller,

Lo-Flo, and In-Line centrifugal pump will not move liquid

unless the pump is primed. A pump is said to be

“primed” when the casing and the suction piping are

completely filled with liquid. Open discharge valves a

slight amount. This will allow any entrapped air to

escape and will normally allow the pump to prime, if the

suction source is above the pump. When a condition

exists where the suction pressure may drop below the

pump’s capability, it is advisable to add a low-pressure

control device to shut the pump down when the

pressure drops below a predetermined minimum.