VXI VT1422A User Manual

Page 415

Advertising
background image

VT1422A Command Reference 413

Chapter 7

Command Quick Reference

SENse:FUNCtion (continued)

:RESistance <excite_current>,[<range>,](@<ch_list>)

Configure channels to sense resistance measurements

:STRain

Links measurement channels as having read bridge voltage from:

:FBENding [<range>,](@<ch_list>)

Full BENding

:POST [<range>,](@<exc_ch>),(@<ch_list>)

Links post-processing strain EU conversion with specified VT1529B channels

:FBPoisson [<range>,](@<ch_list>)

Full Bending Poisson

:POST [<range>,](@<exc_ch>),(@<ch_list>)

Links post-processing strain EU conversion with specified VT1529B channels

:FPOisson [<range>,](@<ch_list>)

Full POisson

:POST [<range>,](@<exc_ch>),(@<ch_list>)

Links post-processing strain EU conversion with specified VT1529B channels

:HBENding [<range>,](@<ch_list>)

Half BENding

:POST [<range>,](@<exc_ch>),(@<ch_list>)

Links post-processing strain EU conversion with specified VT1529B channels

:HPOisson [<range>,](@<ch_list>)

Half Poisson

:POST [<range>,](@<exc_ch>),(@<ch_list>)

Links post-processing strain EU conversion with specified VT1529B channels

[:QUARter] [<range>,](@<ch_list>)

QUARter

:POST [<range>,](@<exc_ch>),(@<ch_list>)

Links post-processing strain EU conversion with specified VT1529B channels

:Q120 [<range>,](@<ch_list>)

Quarter bridge with the 120

Ω resistor selected (VT1529A/B only)

:POST [<range>,](@<exc_ch>),(@<ch_list>)

Links post-processing strain EU conversion with specified VT1529B channels

:Q350 [<range>,](@<ch_list>)

Quarter bridge with the 350

Ω resistor selected (VT1529A/B only)

:POST [<range>,](@<exc_ch>),(@<ch_list>)

Links post-processing strain EU conversion with specified VT1529B channels

:USER [<range>,](@<ch_list>)

Quarter bridge with the user supplied resistor selected (VT1529A/B only)

:POST [<range>,](@<exc_ch>),(@<ch_list>)

Links post-processing strain EU conversion with specified VT1529B channels

RTD, 85 | 92

RTDs

TCouple, CUST | E | EEXT | J | K | N | S | T

thermocouples

THERmistor, 2250 | 5000 | 10000

thermistors

:TEMPerature <sensor_type>,<sub_type>,

[<range>,](@<ch_list>)

Configure channels for temperature measurement types above:

excitation current comes from Current Output SCP.

:POST TC, <sub_type>,[<range>,](@<ch_list>)

Links VT1529B channels to post-processing temperature EU conversion

:TOTalize (@<ch_list>)

Configure channels to count digital state transitions

:VOLTage[:DC] [<range>,](@<ch_list>)

Configure channels for dc voltage measurement

RTD, 85 | 92

RTDs

THERmistor,5000

thermistors

REFerence <sensor_type>,<sub_type>,[<range>,](@<ch_list>)

Configure channel for reference temperature measurements above:

:POST THERmistor, <resistance>,[<range>],

(@<exc_ch>),(@<thr_ch>)

Links thermistor channel to excitation voltage channel and to reference

junction temperature EU conversion

:CHANnels (@<ref_channel>),(@<ch_list>)

Groups reference temperature channel with TC measurement channels

:POST (@ref_channel>), (@<ch_list>)

Links thermocouple channels to temperature reference (thermistor) channel

:TEMPerature <degrees_c>

Specifies the temperature of a controlled temperature reference junction

:POST <degrees_c>, (@<ch_list>)

Stores fixed reference junction temperature for post-processing EU

conversions for specified thermocouple channels

:THERmistor

:RESistance:POST <resistance>, (@<thr_list>)

Specifies sum of resistor values in thermistor divider circuit for specified

thermistor channels when using VT1529B for temperature measurements

:RESistance:POST? (@<thr_ch>)

Returns programmed sum of resistor values in thermistor divider circuit

SCPI Command Quick Reference

Command

Description

Advertising
This manual is related to the following products: