VT1422A Command Reference 245

Chapter 7

ALGorithm

ALGorithm[:EXPLicit]:SCALar?

ALGorithm[:EXPLicit]:SCALar? ’<alg_name>’,’<var_name>’

returns the value of

the scalar variable <var_name> in algorithm <alg_name>.

Parameters

Comments

An error is generated if <alg_name> or <var_name> is not defined.

Returned Value: numeric value. The type is float32.

Use VXIplug&play function: hpe1422_algExpScal_Q(...)

ALGorithm[:EXPLicit]:SCAN:RATio

ALGorithm[:EXPLicit]:SCAN:RATio ’<alg_name>’,<num_trigs>

specifies the

number of scan triggers that must occur for each execution of algorithm <alg_name>.
This allows the specified algorithm to be executed less often than other algorithms.
This can be useful for algorithm tuning.

Notes

1. The command ALG:SCAN:RATio <alg_name>,<num_trigs> does not take

effect until an ALG:UPDATE or ALG:UPD:CHAN command is received.
This allows multiple ALG:SCAN:RATIO commands to be sent with their
effect synchronized with an ALG:UPDATE command.

2. ALG:SCAN:RATio places a variable update request in the Update Queue.

More update requests cannot be placed in the Update Queue than are allowed
by the current setting of ALG:UPD:WINDOW or a "Too many updates ––
send ALG:UPDATE command" error message will be generated.

Parameters

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

alg_name

string

ALG1 - ALG32

none

var_name

string

valid 'C' variable name

none

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

alg_name

string

ALG1 - ALG32

none

num_trigs

numeric (int16)

1 to 32,767