VT1422A Command Reference 297

Chapter 7

INPut

INPut

The INPut subsystem controls configuration of programmable input Signal
Conditioning Plug-Ons (SCPs).

Subsystem Syntax

INPut

:FILTer

[:LPASs]

:FREQuency <cutoff_freq>,(@<ch_list>)
:FREQuency? (@<channel>)
[:STATe] 1 | 0 | ON | OFF,(@<channel>)
[:STATe]? (@<channel>)

:GAIN <chan_gain>,(@<ch_list>)
:GAIN? (@<channel>)
:LOW <wvolt_type>,(@<ch_list>)
:LOW? (@<channel>)
:POLarity NORMal | INVerted,(@<ch_list>)
:POLarity? (@<channel>)

INPut:FILTer[:LPASs]:FREQuency

INPut:FILTer[:LPASs]:FREQuency <cutoff_freq>,(@<ch_list>)

sets the cutoff

frequency of the filter on the specified channels.

Parameters

Comments

The <cutoff_freq> parameter may be specified in kilohertz (kHz). A

programmable Filter in either an SCP or a Remote Signal Conditioning unit
(RSC) has a choice of several discrete cutoff frequencies. The cutoff frequency
set will be the one closest to the value specified by <cutoff_freq>.

For the VT1529A/B, this command affects an 8-channel bank, not a single

channel.

Sending MAX for the <cutoff_freq> selects the SCP or RSC's highest cutoff

frequency. Sending MIN for the <cutoff_freq> selects the SCP or RSC's lowest
cutoff frequency. To disable filtering (the "pass through" mode), execute the
INP:FILT:STATE OFF command.

Sending a value greater than the SCP's highest cutoff frequency or less than the

SCP's lowest cutoff frequency generates a -222 "Data out of range" error.

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

cutoff_freq

numeric (float32)

(string)

see comment |

MIN | MAX

Hz

ch_list

channel list (string)

100 - 15731

none