298 VT1422A Command Reference

Chapter 7

INPut

When Accepted: Not while INITiated

Related Commands: INP:FILT:FREQ?, INP:FILT:STAT ON | OFF

*RST Condition: generally set to MIN. The VT1529A/B is set to 10 Hz.

Send with VXIplug&play Function: hpe1422_cmd(...)

Usage

INP:FILT:FREQ 100,(@100:119)

Set cutoff frequency of 100 Hz for first
20 channels

INPUT:FILTER:FREQ 2,(@15622)

Set cutoff frequency of 2 Hz for RSC
channel 15622

INPut:FILTer[:LPASs]:FREQuency?

INPut:FILTer[:LPASs]:FREQuency? (@<channel>)

returns the cutoff frequency

currently set for channel. Non-programmable SCP channels may be queried to
determine their fixed cutoff frequency. If the channel is not on an input SCP,
the query will return zero.

Parameters

Comments

The <channel> parameter must specify a single channel only.

This command is for programmable filter SCPs only.

Returned Value: Numeric value of Hz as set by the INP:FILT:FREQ command.

The data type is float32.

When Accepted: Not while INITiated

Related Commands: INP:FILT:LPAS:FREQ, INP:FILT:STATE

*RST Condition: generally set to MIN. The VT1529A/B is set to 10 Hz.

Send with VXIplug&play Function: hpe1422_cmdReal64_Q(...)

Usage

INPUT:FILTER:LPASS:FREQUENCY? (@155)

Check cutoff freq on channel 55

INP:FILT:FREQ? (@10024)

Check cutoff freq on RSC channel 0024

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

channel

channel list (string)

100 - 15731

none