322 VT1422A Command Reference

Chapter 7

OUTPut

OUTPut:VOLTage:AMPLitude

OUTPut:VOLTage:AMPLitude <amplitude>,(@<ch_list>)

sets the excitation

voltage on programmable Strain Bridge Completion SCPs pointed to by <ch_list>
(the VT1511A for example).

Note

This command is not used to set output voltage on SCPs like the VT1531A Voltage
Output SCP.

Parameters

Comments

To turn off excitation voltage (when using external voltage source) program

<amplitude> to 0.

Related Commands: OUTP:VOLT:AMPL?

*RST Condition: MIN (0) for VT1511A

Send with VXIplug&play Function: hpe1422_cmd(...)

Usage

OUTP:VOLT:AMPL 5,(@116:119)

set excitation voltage for channels 16
through 19

OUTPut:VOLTage:AMPLitude?

OUTPut:VOLTage:AMPLitude? (@<channel>)

returns the current setting of

excitation voltage for the channel specified by <channel>. If the channel is not on a
VT1511A SCP, the query will return zero.

Comments

The <channel> parameter must specify a single channel only.

Returned Value: Numeric, one of 0, 1, 2, 5, or 10 for VT1511A SCP, 3.9 for

non- programmable VT1506A/07A SCPs. Data type is float32.

Related Commands: OUTP:VOLT:AMPL

Send with VXIplug&play Function: hpe1422_cmdReal64_Q(...)

Usage

OUTP:VOLT:AMPL? (@103)

returns current setting of excitation
voltage for channel 3

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

amplitude

numeric (float32)

MIN | 0 |1 | 2 | 5 | 10 | MAX

none

ch_list

channel list (string)

100 - 163

none