342 VT1422A Command Reference

Chapter 7

[SENSe]

[SENSe:]FUNCtion:CUSTom:REFerence

[SENSe:]FUNCtion:CUSTom:REFerence [<range>,](@<ch_list>)

links channels

with the custom Engineering Unit Conversion table loaded with the
DIAG:CUST:PIECE command. Measurements from a channel linked with
SENS:FUNC:CUST:REF will result in a temperature that is sent to the Reference
Temperature Register. This command is used to measure the temperature of an
isothermal reference panel using custom characterized RTDs or thermistors.

Parameters

Comments

See “Creating and Loading Custom EU Conversion Tables” on page 150.

The VT1422A has five ranges: 0.0625 V dc, 0.25 V dc, 1 V dc, 4 V dc, and

16 V dc. To select a range, simply specify the range value (for example, 4 selects
the 4 V dc range). If a value is specified that is larger than one of the first four
ranges, the VT1422A selects the next higher range (for example, 4.1 selects the
16 V dc range). Specifying a value larger than 16 generates an error. Specifying
0 selects the lowest range (0.0625 V dc). Specifying AUTO selects auto range.
The default range (no range parameter specified) is auto range.

If using amplifier SCPs, set them first and keep their settings in mind when

specifying a range setting. For instance, if the expected signal voltage is to be
approximately 0.1 V dc and the amplifier SCP for that channel has a gain of 8,
<range> must be set no lower than 1 V dc or an input out-of-range condition
will exist.

The *CAL? command calibrates temperature channels based on Sense Amplifier

SCP setup at the time of execution. If SCP settings are changed, those channels
are no longer calibrated. *CAL? must be executed again.

Related Commands: DIAG:CUST:PIEC, SENS:FUNC:TEMP,

SENS:FUNC:CUST:TC, *CAL?

*RST Condition: all custom EU tables erased

Send with VXIplug&play Function: hpe1422_cmd(...)

Usage

program must put table constants into array table_block

DIAG:CUST:PIEC 1,table_block,(@108)

send characterized reference transducer
table for use by channel 8

SENS:FUNC:CUST:REF .25,(@108)

link custom ref temp EU with ch 8

include this channel in a scan list with thermocouple channels (REF channel first)

INITiate then TRIGger module

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

range

numeric (float32)

see comments

V dc

ch_list

channel list (string)

100 - 163

none