Trigger:count, Parameters, Comments – VXI VT1422A User Manual

Page 397: Usage, Trigger:count trigger:count

Advertising
background image

VT1422A Command Reference 395

Chapter 7

TRIGger

TRIGger:COUNt

TRIGger:COUNt <trig_count>

sets the number of times the module can be

triggered before it returns to the Trigger Idle State. The default count is 1. Note that
this default was chosen to make testing data acquisition scan lists easier (only one
scan list worth of data in FIFO per trigger). For algorithm operation, it is usually
desirable to change the count to INFinite to accept continuous triggers. See Figure 7-7
on page 394.

Parameters

Comments

When <trig_count> is set to 0 or INF, the trigger counter is disabled. Once

INITiated the module will return to the Waiting-For-Trigger State after each
trigger event. The ABORT (preferred) and *RST commands will return the
module to the Trigger Idle State. ABORT is preferred since *RST also returns
other module configurations to their default settings.

The default count is 0.

Related Commands: TRIG:COUNT?

*RST Condition: TRIG:COUNT 0

Send with VXIplug&play Function: hpe1422_cmd(...)

Usage

TRIG:COUNT 10

Set the module to make ten passes all
enabled algorithms.

TRIG:COUNT 0

Set the module to accept unlimited
triggers (the default)

TRIGger:COUNt?

TRIGger:COUNt?

returns the currently set trigger count.

Comments

If TRIG:COUNt? returns 0, the trigger counter is disabled and the module will

accept an unlimited number of trigger events.

Returned Value: Numeric 0 through 65,535. The data type is int32.

Related Commands: TRIG:COUNT

*RST Condition: TRIG:COUNT? returns 0

Send with VXIplug&play Function: hpe1422_cmdInt32_Q(...)

Usage

TRIG:COUNT?

Query for trigger count setting

enter statement

Returns the TRIG:COUNT setting

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

Trig_count

numeric (uint16)

(string)

0 to 65535 | INF

none