Trigger[:immediate, Comments, Usage – VXI VT1422A User Manual

Page 398: Trigger:source, Parameters, Trigger[:immediate] trigger:source

Advertising
background image

396 VT1422A Command Reference

Chapter 7

TRIGger

TRIGger[:IMMediate]

TRIGger[:IMMediate]

causes one trigger when the module is set to the TRIG:SOUR

BUS or TRIG:SOUR HOLD mode.

Comments

This command is equivalent to the *TRG common command or the IEEE-488.2

"GET" bus command.

Related Commands: TRIG:SOURCE

Use VXIplug&play function: hpe1422_trigImm(...)

Usage

TRIG:IMM

Use TRIGGER to start a measurement scan

TRIGger:SOURce

TRIGger:SOURce <trig_source>

configures the trigger system to respond to

the trigger event.

Parameters

Comments

The following table explains the possible choices.

Note

The ARM system only exists while TRIG:SOUR is TIMer. When TRIG:SOUR
is not TIMer, SCPI compatibility requires that ARM:SOUR be IMM or an
Error -221,"Settings conflict" will be generated.

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

trig_source

discrete (string)

BUS | EXT | HOLD | IMM | SCP | TIM

| TTLTrg<n>

none

BUS

TRIGger[:IMMediate], *TRG, GET (for GPIB)

EXTernal

“TRG” signal on terminal module

HOLD

TRIGger[:IMMediate]

IMMediate

The trigger event is always satisfied.

SCP

SCP Trigger Bus (future SCP Breadboard)

TIMer

The internal trigger timer

TTLTrg<n>

The VXIbus TTLTRG lines (n=0 through 7)