Zone Types

00 = Zone Not Used
01 = Entry/Exit #1
02 = not used
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
07 = 24 Hr Audible

08 = 24 Hr Aux
09 = Fire
10 = Interior w/Delay
20 = Arm Stay*
21 = Arm-Away*
22 = Disarm*
23 = No Alarm

Response

* 5800 RF Systems only

When the display shows the zone type you
want, press [

✱

] to continue.

You must enter “00” as the zone type for any hard-wired zones that are not
used.

02 Report Code

1st 03 2nd 12

3C

The report code consists of 2 hexadecimal
digits, each in turn consisting of 2 numerical
digits. For example, for a report code of "3C",
enter [0][3] for "3" and [1][2] for "C". Refer to the
SYSTEM COMMUNICATION section f o r
complete information on report codes, if
necessary.
Enter the desired report code and then press [

✱

]

to continue.

Typical summary display

Zn ZT – RC

In

L

02

03

– 3C

HW: –

A summary display will appear, showing the
data for the zone that was just programmed.
If it is programmed satisfactorily, press [

✱

] to

continue.

Program Alpha?

0 = No 1 = Yes

0

The next request is to enter Alpha descriptors
for the zones. The entry may be done now
(enter 1), or may be done at a later time using

✱

82 interactive mode (enter 0). See the

ALPHA

DESCRIPTOR PROGRAMMING section for
specific procedure.

Enter Zn Num.

(00 = Quit)

03

Enter next zone number

↑

If “0” (no) was entered above, the system will
return to the Enter Zone Number prompt.
Proceed with the programming for the next
zone, i.e., [

✱

] and zone number.

Programming Panic Keys

When programming zones, note the following:
The defaults for individual panic keys or panic key pairs are:

Zone 07.

✱

& #, or

B: zone type 06 (24-hr silent).

Zone 95. 1 &

✱

, or A: zone type 00 (not used).

Zone 96. 3 & #, or C: zone type 00 (not used).

Panic keys are programmed (or re-programmed) by keying the zone number,
e.g.,

✱

07,

✱

95, and

✱

96, and entering the desired zone type that will provide

the desired panic function for each of these keys, using the list of zone types
below.

06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire