Zone Types

00 = Zone Not Used
01 = Entry/Exit #1
02 = not used
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
07 = 24 Hr Audible

08 = 24 Hr Aux
09 = Fire
10 = Interior w/Delay
20 = Arm Stay*
21 = Arm-Away*
22 = Disarm*
23 = No Alarm

Response

* 5800 RF Systems only

When the display shows the zone type you
want, press [

] to continue.

You must enter “00” as the zone type for any hard-wired zones that are not
used.

02 Report Code

1st 03 2nd 12

3C

The report code consists of 2 hexadecimal
digits, each in turn consisting of 2 numerical
digits. For example, for a report code of "3C",
enter [0][3] for "3" and [1][2] for "C". Refer to the
SYSTEM COMMUNICATION section f o r
complete information on report codes, if
necessary.
Enter the desired report code and then press [

]

to continue.

Typical summary display

Zn ZT – RC

In

L

02

03

– 3C

HW: –

A summary display will appear, showing the
data for the zone that was just programmed.
If it is programmed satisfactorily, press [

] to

continue.

Program Alpha?

0 = No 1 = Yes

0

The next request is to enter Alpha descriptors
for the zones. The entry may be done now
(enter 1), or may be done at a later time using

82 interactive mode (enter 0). See the

ALPHA

DESCRIPTOR PROGRAMMING section for
specific procedure.

Enter Zn Num.

(00 = Quit)

03

Enter next zone number

If “0” (no) was entered above, the system will
return to the Enter Zone Number prompt.
Proceed with the programming for the next
zone, i.e., [

] and zone number.

Programming Panic Keys

When programming zones, note the following:
The defaults for individual panic keys or panic key pairs are:

Zone 07.

& #, or

B: zone type 06 (24-hr silent).

Zone 95. 1 &

, or A: zone type 00 (not used).

Zone 96. 3 & #, or C: zone type 00 (not used).

Panic keys are programmed (or re-programmed) by keying the zone number,
e.g.,

07,

95, and

96, and entering the desired zone type that will provide

the desired panic function for each of these keys, using the list of zone types
below.

06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire