VistaQuest N7227V5 User Manual

Page 65

Advertising
background image

– 65 –

3+1/4+1

3+1/4+1

Report Standard

Expanded

4+2

Alarm SSS(S) A

SSS(S) A

SSSS AZ

AAA(A) Z

Trouble

SSS(S) T

SSS(S) T

SSSS Tt

TTT(T) t

Bypass

SSS(S) B

SSS(S) B

SSSS Bb

BBB(B) b

AC Loss

SSS(S) E

SSS(S) E

SSSS EA C

EEE(E) A C

Low Batt

SSS(S) L

SSS(S) L

SSSS LL B

LLL(L) L B

Open

SSS(S) O

SSS(S) O

SSSS OU

OOO(O) U

Close

SSS(S) C

SSS(S) C

SSSS CU

CCC(C) U

Test

SSS(S) G

SSS(S) G

SSSS Gg

GGG(G)g

Restore

SSS(S) R

SSS(S) R

SSSS RZ

Alarm

RRR(R) Z

AC Restore

SSS(S) R A

SSS(S) R A

SSSSR A Ac

RARARA(RA)Ac

LoBat Res.

SSS(S) R L

SSS(S) R L SSSS

RLLB

RLRLRL(RL)LB

Trouble Res.

SSS(S) R T

SSS(S) R T SSSS

RTt

RTRTRT (RT)t

Bypass Res.

SSS(S) R B

SSS(S) R B

SSSS RBb

RBRBRB (RB)b

Where:

Where:

SSS or SSSS = Subscriber ID

C = Close Code–1st Digit

A = Alarm Code–1st digit

U = User Number (in hex)

Z = Typically Zone Number*–2nd digit

G g = Test Code (1st & 2nd digits)

T t = Trouble Code (1st & 2nd digits)

R = Restore Code (Alarm)

Bb = Bypass Code (1st & 2nd digits)

R T t = Restore Code (Trbl)1st & 2nd digits

EAC = AC Loss Code (1st & 2nd digits)

R Bb = Restore Code (Byps)1st & 2nd digits

LLB = Low Battery Code(1st & 2nd digits)

R AAC = Restore Code (AC)1st & 2nd digits

O = Open Code–1st Digit

R LLB = Restore Code (Bat)1st & 2nd digits

*Zone numbers for:

[

] & [#], or [B] = 99

[1] + [

], or [A] = 95

Duress = 8

[3] + [#], or [C] = 96

Tamper = 9

Ademco Contact ID Reporting takes the following format:

CCCC Q EEE GG ZZZ

where: CCCC = Customer (subscriber) ID

Q = Event qualifier, where:

E = new event , and R = restore

EEE =

Event code (3 hexadecimal digits)
Note:

For a complete list of event codes, refer to the
central office receiver manual.

GG = Always 00.

ZZZ =

Zone/contact ID number reporting the alarm, or user
number for open/close reports. System status
messages (AC Loss, Walk Test, etc.) contain zeroes
in the ZZZ loca tion.

Advertising