VistaQuest N7227V5 User Manual

Page 67

Advertising
background image

– 67 –

Press

✱

45 PHONE SYSTEM SELECT Enter 1 digit (default = 0)

If Central Station Receiver

is not on WATS line:

0 = Pulse Dial, 1 = Tone Dial.
If Central Station Receiver

is on WATS line:

2 = Pulse Dial, 3 = Tone Dial.

Press

✱

46

REPORT FORMAT, PRIMARY/SECONDARY
Determines which format is to be used to report to the central
station.
0 = 3+1; 4+1 ADEMCO Lo Speed Standard (this is the default)
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Lo Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID Reporting
8 = 3+1; 4+1 ADEMCO Lo Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
(Enter

✱

as the 4th digit of

✱

43 if 3+1 dialer reporting is to be

used.)

Note: The maximum number of alarm and alarm restore reports

during one armed period is determined by field

✱

92.

Press

✱

47 SPLIT/DUAL REPORTING

Enter 0 to disable (Backup report only). This is the default.

*

Can only be used if
Primary reporting format
is Ademco Contact ID.
If reporting to Pager,
choose from 6, 7, 8, or 9,
as desired.

TO PRIMARY PHONE No.

TO SECONDARY PHONE No.

1 =

Alarms, Restore, Cancel

Other Reports

2 =

All except Open/Close, Test

Open/Close, Test

3 =

Alarms, Restore, Cancel

All reports

4 =

All except Open/Close, Test

All reports

5 =

All reports

All reports

TO PRIMARY PHONE #

TO PAGING NUMBER

*

6 =

All reports except Open/Close

Alarms, Open/Close, Troubles

7 =

All reports

Alarms, Troubles

8 =

All reports

Alarms, Open/Close, Troubles

9 =

All reports except Open/Close

Alarms, Open/Close for User
Nos. 5–25

‡, Troubles

‡

Will report only Users 5–8. If using wireless button-type devices, the zone

number of the arm or disarm button (10–25) will be sent as the user number.

Entries 6 through 9 will send a report to a pager (in addition to the selected
primary phone number), but you must enter the pager number as the
secondary phone number in field

✱

42.

A 10-digit code is sent to the pager which will take the following format:

†

4-digit Subscriber No.

→

SSSS

–

EEE

–

NNN

←

3-digit

User or Zone No.

(as entered in field

✱

43)

↑

3-Digit Event Code, as follows:

911 = Alarm (NNN = Zone No.)
001 = Open, System disarmed (NNN = User No.)
002 = Close, System armed (

NNN = User No.)

811 = Trouble (

NNN = Zone No.)

†

The first digit of the Subscriber No. entered in field

✱

43 must be 1–9 (DO NOT

USE “0”); the last 3 digits can be 0–9. Failure to observe this requirement may
interfere with paging services.

(continued)

Advertising