– 42 –

Output Relay Displays

Enter Relay No.
(00 = Quit)

01

Upon pressing

80, this screen will appear. Enter the Relay Number 01, 02,

03, or 04 for a 4204 (or 00 to end these entries). Press the [

] key to

continue.

The [

] key is used to accept an entry and advance to the next prompt. The

[#] key is used to revert back to the last question to check or change an
entry. Press [

] to go forward again.

02 A EV ZL ZT
STT

0 0 0

00

This screen displays a summary of the current Relay START programming
(for this example, relay 02 has been selected).
Press the [

] key to continue.

02 A EV ZL ZT
STP – – 0 00

This screen displays a summary of the current Relay STOP programming.
Press the [

] key to continue.

02 Relay Action
No Response

0

Enter the desired relay action as listed below. Press the [

] key to continue.

0 = No response

2 = Close and Stay Closed

1 = Close for 2 seconds

3 = Continuous Pulse on & off

( 1 sec ON, 1 sec OFF)

02 Start Event
Not Used

0

Enter the event to START the relay:
0 = Not used; 2 = Fault; 1 = Alarm; 3 = Trouble
A zone list must be used in conjunction with an event. If a zone type/system
operation is to be used instead of an event, enter 0.
Press the [

] key to continue.

02 Start:

Zn List

No List

0

If a zone list will be used to START the relay action, enter the zone list number
(to be programmed in field

81): 1, 2, or 3. If not used, enter 0. Press the [

]

key to continue.

02 Start:

Zn Typ

Not Used

00

If a zone type or system operation will be used to START the relay action,
enter the appropriate two-digit code (see table that follows). If not, enter 00.
Press the [

] key to continue.

CHOICES FOR ZONE TYPES

00 = Not Used

05 = Trouble Day/Alarm Night 08 = 24 Hr Aux

01 = Entry/Exit

06 = 24 Hr Silent

09 = Fire

03 = Perimeter

07 = 24 Hr Audible

10 = Interior w/Delay

04 = Interior Follower

CHOICES FOR SYSTEM OPERATION

20 = Arming–Stay

33 = Any Burglary Alarm

39 = Any Fire Alarm

21 = Arming–Away

34 = Code + # + 7 Key Entry

40 = Bypassing

22 = Disarming (Code + OFF)

35 = Code + # + 8 Key Entry

41 = AC Power Failure

31 = End of Exit Time

36 = At Bell Timeout**

42 = System Batt. Low

32 = Start of Entry Time

38 = Chime

58 = Duress

**Or at Disarming, whichever occurs earlier.

02 Stop:

Zn List

No List

0

If a zone list will be used to STOP, or restore, the relay action, enter the zone list
(ZL) number 1, 2, or 3 (to be programmed in

81 mode). If not used, enter 0.

Press the [

] key to continue.

02 Stop:

Zn Typ

Not Used

00

If a zone type or system operation will be used to STOP the relay action, enter
the appropriate two digit code (see the "ZT" choices listed above). If not, enter
00. Press the [

] key to continue.

02 A EV ZL ZT
STT 0 0 0 00

This screen again displays a summary of the current relay START
programming.
Press the [

] key to continue.

02 A EV ZL ZT
STP – – 0 00

This screen again displays a summary of the current relay STOP programming.
Press the [

] key to continue.