VistaQuest N7227V5 User Manual

Page 68

Advertising
background image

– 68 –

Example 1.

Pager displays:

1 2 3 4

9 1 1

0 0 4  

This indicates that Subscriber No.

1234’s system is reporting an Alarm (911),

due to zone 4 being faulted (004).

Example 2.

Pager displays:

1 2 3 4

0 0 1

0 0 5

This indicates that Subscriber No.

1234’s system is reporting an opening (001)

by User 5 (005).
Note that no restore reports are sent to the pager.

Important: Do not use AAV when Paging or Alarm Reports are being sent to
a Secondary number. If this is done, the call to the Secondary number by the
communicator after the alarm report will prevent the AAV from taking control
of the phone line, and the AAV “Listen in” session cannot take place.

Press

48

15-SECOND DIALER DELAY, BURGLARY

Enter 0 for no, or 1 for yes. Default is 0 (no delay).

Press

49

PERIODIC TEST REPORT
Select the desired test report interval.
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days. Default is 0
(none). Test Report Code entered in field

64 is sent.

Reports with Subscriber No.

Press

50

SESCOA/RADIONICS SELECT

0 = Radionics (0–9, B–F reporting)
1 = SESCOA (0–9 only reporting)
Select 0 for all other formats. Default is 0.

TO PROGRAM SYSTEM

STATUS AND

RESTORE REPORT

CODES

(

60 –

68,

70 –

75)

With a 3+1 or 4+1 Standard Format: Enter a code in the

first digit box:

1–9, 0, B, C, D, E, or F. Enter "# + 10" for 0, "# + 11" for B, "# + 12" for C,
"# + 13" for D, "# + 14" for E, "# + 15" for F.

A "0" (

not "# + 10") in the first digit box will disable a report.

A "0" (

not "# + 10") in the second digit box (if any) will result in automatic

advance to the next field when programming.

With an Expanded or 4+2 Format: Enter codes in

both boxes (1st and 2nd

digits) for 1–9, 0, or B–F, as described above.

A "0" (

not "# + 10") in the second box will eliminate the expanded message

for that report.
A "0" (

not "# + 10") in both boxes will disable the re port.

With Ademco Contact ID Reporting: Enter any digit (other than "0") in the
first box, to enable zone to report This is an "enabling" code only and is
disregarded in the actual reporting to the central office. Entries in the

second

boxes will be ignored.

A "0" (

not "# + 10") in the first box will disable the report.

Examples:

For Code 3 (Single Digit), enter:

3

0

For Code 32 (Two Digits), enter:

3

2

For Code B2 (Hexadecimal) enter:

# +

11

2

Press

60 TROUBLE REPORT CODE

This will be sent if a zone goes into trouble.

Press

61 BYPASS REPORT CODE

This will be sent when a zone is manually bypassed.

Press

62 AC LOSS REPORT CODE

Reports with Subscriber No. Timing of this report is random with
up to a 48-minute delay. The Restore report has a random delay
of up to about 12 minutes. If AC restores before the report goes
out, there is no AC restore report.

Advertising