LOW BAT REPORT CODE
This will be sent when a low battery condition exists in the
system’s standby battery.
Note: Connection to the standby battery is checked every 3
minutes (CSFM requirement).

Press

64

TEST REPORT CODE
This is sent periodically to test that the communicator and phone
lines are operational (frequency of report is selected in field

51).

Press

65

OPEN/EXIT ALARM REPORT CODE, 1st DIGITS
Open Report Code :
To enable, enter a code (or 0 to disable) in
the left-hand box (see box on previous page).
For expanded or 4+2 reporting, 2nd digit = User #.
Exit Alarm Report Code: To enable, enter a code (or 0 to
disable) in the right-hand box (see box above). If enabled, any
alarm from an exit or interior zone occurring within two
minutes after the end of the exit delay
will send a special
message indicating exit alarm to the central station, and a zone
indication and "Exit Alarm" or "EA" is displayed on the keypad.
If an exit or interior zone contains a fault as the exit delay
ends
, the local bell and keypad sound continuously.
a)

If the subscriber then disarms the system before the ensuing
ENTRY delay ends , no message is transmitted to the central
station, but a zone indication and "Canceled Alarm" or "CA" is
displayed on the keypad.

b)

If the system is not disarmed before that entry delay ends, a
special message indicating Exit Alarm is sent to the central
station and a zone indication and "Exit Alarm" or "EA" is
displayed on the keypad.

For expanded or 4+2 reporting, a 2nd digit is sent, and is the
same as the 2nd digit of the zone alarm report code programmed
in field

56.

For Contact ID reporting, Event code 374 and the zone number is
sent.
There is no restore message for Exit Alarm report.

Press

66 ARM AWAY/STAY REPORT CODES

This option allows for independent programming of AWAY and
STAY reports . 2nd digit of Report is User No., if expanded or 4+2
reporting is selected.

Press

67 RF XMTR. LOW BATTERY REPORT CODE

This is sent in the event that a wireless transmitter low battery
condition exists.

Press

68 CANCEL REPORT CODE

This is sent upon disarming of the system after an alarm condition
was reported.

Press

70 ALARM RESTORE REPORT CODE, 1st DIGIT

This is sent when the zone that caused an alarm is restored to its
non-faulted condition. 2nd digit is automatically sent as the 2nd
digit of the zone alarm report code programmed in field

56, if

expanded or 4+2 reporting is selected.

Press

71 TROUBLE RESTORE REPORT CODE

This is sent when a trouble in a zone is restored.

Press

72 BYPASS RESTORE REPORT CODE

This is sent when a zone that has been bypassed is un-bypassed.

Press

73 AC RESTORE REPORT CODE

This is sent when AC power has been restored after an AC power
outage.