VistaQuest N7227V5 User Manual

Page 69

Advertising
background image

– 69 –

Press

✱

63

LOW BAT REPORT CODE
This will be sent when a low battery condition exists in the
system’s standby battery.
Note: Connection to the standby battery is checked every 3
minutes (CSFM requirement).

Press

✱

64

TEST REPORT CODE
This is sent periodically to test that the communicator and phone
lines are operational (frequency of report is selected in field

✱

51).

Press

✱

65

OPEN/EXIT ALARM REPORT CODE, 1st DIGITS
Open Report Code :
To enable, enter a code (or 0 to disable) in
the left-hand box (see box on previous page).
For expanded or 4+2 reporting, 2nd digit = User #.
Exit Alarm Report Code: To enable, enter a code (or 0 to
disable) in the right-hand box (see box above). If enabled, any
alarm from an exit or interior zone occurring within two
minutes after the end of the exit delay
will send a special
message indicating exit alarm to the central station, and a zone
indication and "Exit Alarm" or "EA" is displayed on the keypad.
If an exit or interior zone contains a fault as the exit delay
ends
, the local bell and keypad sound continuously.
a)

If the subscriber then disarms the system before the ensuing
ENTRY delay ends , no message is transmitted to the central
station, but a zone indication and "Canceled Alarm" or "CA" is
displayed on the keypad.

b)

If the system is not disarmed before that entry delay ends, a
special message indicating Exit Alarm is sent to the central
station and a zone indication and "Exit Alarm" or "EA" is
displayed on the keypad.

For expanded or 4+2 reporting, a 2nd digit is sent, and is the
same as the 2nd digit of the zone alarm report code programmed
in field

✱

56.

For Contact ID reporting, Event code 374 and the zone number is
sent.
There is no restore message for Exit Alarm report.

Press

✱

66 ARM AWAY/STAY REPORT CODES

This option allows for independent programming of AWAY and
STAY reports . 2nd digit of Report is User No., if expanded or 4+2
reporting is selected.

Press

✱

67 RF XMTR. LOW BATTERY REPORT CODE

This is sent in the event that a wireless transmitter low battery
condition exists.

Press

✱

68 CANCEL REPORT CODE

This is sent upon disarming of the system after an alarm condition
was reported.

Press

✱

70 ALARM RESTORE REPORT CODE, 1st DIGIT

This is sent when the zone that caused an alarm is restored to its
non-faulted condition. 2nd digit is automatically sent as the 2nd
digit of the zone alarm report code programmed in field

✱

56, if

expanded or 4+2 reporting is selected.

Press

✱

71 TROUBLE RESTORE REPORT CODE

This is sent when a trouble in a zone is restored.

Press

✱

72 BYPASS RESTORE REPORT CODE

This is sent when a zone that has been bypassed is un-bypassed.

Press

✱

73 AC RESTORE REPORT CODE

This is sent when AC power has been restored after an AC power
outage.

Advertising