– 35 –

ZN ZT

– R C I n :

L

1 0 0 0

– 0 0 R F :

1

5.

A display will appear, showing a summary of that zone's programming.
If the zone is not programmed, the display will appear as shown here. If
checking a zone's programming, and it is programmed satisfactorily,
press [#] to back up one step and enter another zone number, if
desired. Otherwise, press [

] to continue.

Zone Number

1 0 Zo n e T ype

P e r im e te r

0 3

Entry for Zone Type 03

shown

6.

Each zone must be assigned a zone type, which defines the way in
which the system responds to faults in that zone. Enter the zone type
desired (or change it, if necessary). Available zone types are:

00 = Zone Not Used

08 = 24 Hr Aux

01 = Entry/Exit #1, Burglary

09 = Fire

02 = Not used

10 = Interior w/Delay

03 = Perimeter

20 = Arm–Stay*

04 = Interior Follower

21 = Arm–Away*

05 = Trouble Day/Alarm Night

22 = Disarm*

06 = 24 Hr Silent

23 = No Alarm Response

07 = 24 Hr Audible

(EX: Relay activation)

* These are special zone types used with 5800 series wireless pushbutton

units which will result in arming the system in the STAY or AWAY mode, or
disarming of the system, depending on the selection made. A button
programmed for these functions will report the zone number of the button as
the user number that armed/disarmed to the central station.

Press [

] to continue.

1 0

R e po r t

Co de

1 st 0 3 2 n d 1 2

3 C

7.

Enter the report code. The report code consists of 2 hexadecimal digits,
each in turn consisting of 2 numerical digits. For example, for a report
code of "3C", enter [0][3] for "3" and [1][2] for "C."
(Refer to the

SYSTEM COMMUNICATION section for more informa tion

about report codes and report code formats.)
Press [

] to continue.

10 Input Dev: LP #
Rf Trans. RF: 1

8.

Enter the transmitter input device type as follows:
3 = RF (supervised RF transmitter)
4 = UR (unsupervised RF transmitter)
5 = BR (button type RF transmitter - unsupervised)
(Refer to the separate Programming Guide for input types.)
Press [

] to continue.

10 Input Dev: LP#
RF Trans. RF: 1

9.

The cursor should now be flashing above the loop number. The default
is "1." To accept this, press [

]. If a different loop number is being used

on this transmitter, enter the loop number (1–4) and press [

] to

continue (see the loop designations for various transmitters in the
separate Programming Guide). The loop number must be entered
here, whether using Zone Programming or Sequential Mode to
"enroll" transmitters.

10 Learn S/N?
0 = No, 1 = Yes 0

10. If the transmitter’s serial number has not been previously “enrolled,” you

may enter the enroll mode now by either entering "1" (Yes)

o r by

pressing the upper left-hand button of the “program tool”. If using the
program tool, move to the physical location of the transmitter to be
enrolled before pressing the button.
A single short beep will verify that
the button has been pressed. The system will respond to the first serial
number transmitted after the [

] key on the keypad or the button of the

program tool is pressed.
Enter "0" (No) if you wish to enroll the transmitter later, using the
“sequential” mode in

Section 13. SEQUENTIAL MODE .

If "0" (No) is entered, go to step 13 (skip steps 11 and 12).

10 Input S/N: L
A

X X X–X X X X

11. This prompt is displayed if "1" (Yes) is entered in response to the "Learn

S/N?" prompt. The serial number may be enrolled by one of two methods:

a) Enter the 7-digit serial number printed on the transmitter using a

Alpha keypad, or

b) Activate the transmitter by faulting

or restoring the input you wish to

use for that zone (e.g., press a button, open or close a door, etc.).