The display then returns again to the first screen so that the next relay number
to be programmed can be entered, or enter [0][0] to end relay programming.

Previously entered data can be reviewed by pressing [#] [8] [0]. After the
relay number is chosen, press [

✱

] to go to the next screens. This is a review

mode only, and data cannot be changed.

Example of Output

Relay Programming

A lamp is to be turned on when any one of 3 specific zones are faulted or
when any 24-hour auxiliary zone is disturbed. We want to turn off the
lamp manually without affecting the arming status of the system.

In field *80 we choose Output Relay 01 and program the Ac tion (A) to be "2"
(Close and stay closed). The Event we are looking for to

start the relay action

is a fault, so we will program "2" in (EV). We will use Zone List 1 for the 3
specific zones, so will program "1" in (ZL), (and will program these 3 zones in
field *81's Zone List 1).
The second condition for turning on the indicator is trigger ing a 24 hour aux.
zone (Zone Type 08), so we will program (ZT) as "08".
To

stop relay action and turn off the indicator, we do not want to use a restore

of any zone, so we will program a "0" for the "

Restore of" Zone List (ZL). To

choose a manual entry of User Code + [#] + [7] to turn it off, we will program
(ZT) as "34".
If no other relay is to be programmed we go to field *81 and program the 3
specific zones in Zone List 1.
Press

✱

81. (Zone Lists for Output Relays ). This interactive mode is applicable

only if you have programmed

✱

80 mode.

Refer to the Programming Form worksheet for

✱

81 Mode.

Zone List Displays

↓

Zone List No.

(00 = Quit)

01

Upon keying

✱

81, this screen will appear. Enter the Zone List Number 01, 02,

or 03 to program (or 00 to end these entries). Press the [

✱

] key to advance.

In the following displays, zone list 01 has been selected for programming.

01

Enter Zn Num.

(00 = Quit)

00

Enter each zone number to add to the zone list by first entering the zone
number, then the [

✱

] key (example, 01

✱

, 02

✱

, 03

✱

). After all zones desired

are entered, press 00 to advance.

01 Del Zn List?

0 = No 1 = Yes

0

To delete the zone list, enter 1 (Yes). All zones in the zone list will be deleted
automatically. and programming will return to the first screen.
To save the zone list, enter 0 (No) to advance.

01 Delete Zone?

0 = No 1 = Yes

0

To delete a zone or zones in a zone list enter 1 (Yes) to advance.

01 Zn to Delete?

(00 = Quit)

00

Enter each zone to be deleted from the list, followed by the [

✱

] key. After all

zones to be deleted are entered, enter 00 to return to the first screen so that
another list can be programmed, if desired.

Notes:

• Any list may include any or all of the system's zone numbers.

• A zone list can be assigned to more than one output relay.

•

If you only want to review what has been programmed previously, enter
[#][8][1]. The review can be advanced by using the [

✱

] key. When finished,

enter [0][0]

✱

to quit. No programmed values can be changed in this mode.

When programming in

✱

80 and

✱

81 interactive modes is completed, exit

the programming mode by keying

✱

99.