Doc# 27-0032UM Rev A Issued 07/05

38

* Results of Environmental Tests pending
** Unit will power up and is legible at -20°C; backlight life is reduced

Non-Op Temp

-40° to 70° C

Humidity

5%-95% Non-Condensing

Operating Altitude

Up to 10,000 ft

Non-Op Altitude

Up to 40,000 ft

Vibration

MIL-STD-167

Shock

MIL-STD 810E (Method 516) 30 g’s

MIL-S-901D (in isolated rack)

Sand and Dust

5.5 MPH for 25 mins (display bezel, keyboard and

trackball only)

Drip

MIL-STD-810E (display bezel, keyboard and

trackball only)

Fungus

Non-Nutrients/Contaminants

Reliability

MTBF

Display: 20,000 hrs w/ backlight change at 10,000

hrs.

MRRT

<30 minutes

Safety

UL 1950 (used as a design guideline)

EMI

MIL-STD-461E, RE101 (Army Limits), RE102

(Navy Fixed Limits), RS101, RS103, (20v/m 2MHz

and 60v/m 1GHz-18GHz, CE101, CS114, CS115,

CS116

Quality/Workmanship

IPC/ISO 9001:2000 and applicable section of

MIL-HDBK-454