Analog Programming (APG) and Isolated Analog Programming (ISOL)

4-20

975-0200-01-01

Table 4-4 AUX Output and ISOL Connector Pins and Functions J3

PIn

Reference

Function

J3.1

AUX_ON_OFF

Auxiliary On/Off

J3.2

COM_ISOLATED

Isolated Common (Isolated from Main Output and Communication.
Return wire for +5 V, +15 V Auxiliary Voltage.

J3.3

IS_VOL_PR_VOL

Isolated Analog Voltage Programming Input

J3.4

IS_VOL_PR_CUR

Isolated Analog Current Programming Input

J3.5

IS_MON_VOL

Isolated Voltage Monitor. Scaled to the value of the Voltage Analog
Programming Level.

J3.6

COM_ISOLATED

Isolated Common (Isolated from Main Output and Communication.
Return wire for control signals, monitoring and programming.

J3.7

ISO_CUR_RES_PR

Isolated Current Resistive Programming

J3.8

ISO_VOL_RES_PR

Isolated Voltage Resistive Programming

J3.9

+AUX 1

+5 V Isolated Output

1

1.Use unshielded cable up to 9.84 feet (3 m) length with high-density D-Sub type connector
with ferrite bead (Fair-Rite part number 0443164251).

J3.10

IS_MON_CUR

Isolated Current Monitor. Scaled to the value of the Voltage Analog
Programming Level.

J3.11

+AUX 2

+15 V Isolated Output

1

J3.12

SD

Shutdown

J3.13

PS_GOOD

PS_GOOD. Power supply output enabled.

J3.14

INTER_LOCK 1

Interlock. Is a dry contact type. Shorting pins J3.14 and J3.15 with
the interlock enabled will disable the output of the power supply.

J3.15

INTER_LOCK 2

Interlock

CAUTION: Equipment damage

Do not drive or apply a voltage to pins J3.14 (Inter_Lock 1) or to pins J3.15
(Inter_Lock 2).