SPC

I Co
mmand T

ree

975-0200

-01-01

A-23

A

Self Test

[:]SYSTem[<channel>]:TEST?

Perform unit Self test,
returns 0 if pass, non zero
value for failure.

Yes

ID Query

[:]SYSTem[<channel>]:IDENtify

Query device ID string.

Yes

Save User
Preset

[:]SYSTem[<channel>]:SAVE

Save the user preset values.
Select any slot from 1-5.

<Setting Index

(1–5)>

No

Recall User
Preset
(previously
saved)

[:]SYSTem[<channel>]:RECall

Load the user preset
values. Select any slot from
1-5.

<Setting Index

(1–5)>

No

Query System
Error

[:]SYSTem[<channel>]:ERRor[:NEXT]?

Returns the next error in
the instrument’s error
queue

Yes

Query System
Error Code

[:]SYSTem[<channel>]:ERRor:CODE[:NEXT]

?

Returns the error code only
for the next error in the
instrument’s error queue.

Yes

Query the
Error Queue
for the
number of
entries.

[:]SYSTem[<channel>]:ERRor:COUNt?

Returns the number of
errors currently in the error
queue.

Yes

Select Voltage
Analog
Programming
Input Voltage
Input Level/
Range

[:]SYSTem[<channel>]:COMMunicate

:APRogram:LEVel[:VOLTage][:ISOLated]

Select level for Voltage
APG. Level can be between
2 -10 volts.

?|<Level (2–
10)>|MAXimum|MI
Nimum

Yes