A-16 975-0200-01-01

S

C

PI

C

o

mm

an
d

R

e

fe

re

n

ce

Trigger

*TRG

Trigger system

N/A

Self-Test
Query

*TST?

[:]SYSTem[<channel>]:TEST?

Perform unit Self Test
(Pass=0).

Yes

Wait To
Continue

*WAI

[:]SYSTem[<channel>]:WAIT

Wait to continue command.

N/A

Table A-2 Readback Commands

Function

SCPI Command

Description

Parameter and
Range

Query

Read Output
Current

[:]MEASure[<channel>][:SCALar]:CURRent

[:DC]?

Measure and readback
output current at the
output terminals.

Yes

Read Output
Voltage

[:]MEASure[<channel>][:SCALar][:VOLTage]

[:DC]?

Measure and readback
output voltage at the
output terminals.

Yes

Table A-3 SCPI Commands for Output Control

Function

SCPI Command

Description

Parameter and
Range

Query

Set Output
latches for the
alarms

[[:]SOURce[<channel>]]:COMBine:CSHare

[:MODE]

Sets the output latches for
the alarms.

?|<alarm sum of
latch flags>

Yes

Set
(Immediate)
Current Set
point

[[:]SOURce[<channel>]]:CURRent[:LEVel]

[:IMMediate][:AMPLitude]

Set current set point
(immediate)

?|<Current Set
Point>|MAXimum|
MINimum

Yes

Table A-1 IEEE 488.2 Commands (Continued)