Xantrex Technology XTR 850 Watt User Manual

Page 228

Advertising
background image

A-20 975-0200-01-01

S

C

PI

C

o

mm

an
d

R

e

fe

re

n

ce

Calibrate the
Resistive
controlled
Non Isolated
Voltage APG
feature

[:]CALibration[<channel>]:OUTPut

:ANALog[:VOLTage]:RESistive

Calibrate the Resistive
controlled voltage analog
programming system.

? | <NR1> |
<nothing for
interactive mode>

Yes

Calibrate the
Resistive
controlled
Isolated
Voltage APG
feature

[:]CALibration[<channel>]:OUTPut

:ANALog[:VOLTage] :RESistive:ISOLated

Calibrates the Resistive
controlled voltage analog
programming system.

? | <NR1> |
<nothing for
interactive mode>

Yes

Calibrate the
Resistive
controlled
Non Isolated
Current APG
feature

[:]CALibration[<channel>]:OUTPut

:ANALog:CURRent:RESistive

Calibrate the Resistive
controlled current analog
programming system.

? | <NR1> |
<nothing for
interactive mode>

Yes

Calibrate the
Resistive
controlled
Isolated
Current APG
feature

[:]CALibration[<channel>]:OUTPut

:ANALog:CURRent:RESistive:ISOLated

Calibrates the Resistive
controlled current analog
programming system.

? | <NR1> |
<nothing for
interactive mode>

Yes

Get Ouput
Calibration
Parameters

[:]CALibration[<channel>]:PARameter

[:OUTPut]

Queries and loads the output
calibration parameters in
arbitrary program block data
format.

?|<arbitrary
program block
data>

Yes

Get Analog
Programming
Calibration
Parameters

[:]CALibration[<channel>]:PARameter

:APRogram

Queries and loads the APG
calibration parameters in
arbitrary program block data
format.

?|<arbitray program
block data>

Yes

Table A-4 SCPI Commands for Calibration (Continued)

Advertising