Table 5-10, Standard event status register –30 – Xantrex Technology XTR 850 Watt User Manual

Page 152

Advertising
background image

Remote Operation

5-30

975-0200-01-01

Figure 5-20 summarizes the Standard Event Status Register.

Figure 5-20 Summary of Standard Event Status Register

Table 5-10 Standard Event Status Register

Bit

Bit Weight

Bit Name

Description

0

1

Operation Complete
(OPC)

Set if *OPC command has been received and all
pending operations have been completed.

1

2

Request Control (RQC)

Not implemented. Always set to 0.

2

4

Query Error (QYE)

Not implemented.

3

8

Device Dependent Error
(DDE)

Set if there is a device-specific error.

See “Device-Specific Error List” on page B–4
for a list possible error codes and descriptions.

4

16

Execution Error (EXE)

Set if a program data element, following a header,
was evaluated by the power supply as outside of its
legal input range, or is otherwise inconsistent with
the power supply’s capabilities. Suggests that a
valid program message could not be properly
executed due to some power supply condition.

See “Execution Error List” on page B–3 for a list of
possible error codes and descriptions.