Local Operation

3-36

975-0200-01-01

To reset the power supply:

1. Turn the front panel power switch to the Off position.

2. Allow the unit to power down.

3. When the fans are off and the front panel displays are not illuminated,

turn the power switch to the On position.

4. Press and hold the OUTPUT ON/OFF and AUX ON/OFF buttons.

The front panel should display P5U S rS.

5. When the display reads P5u Clr, release the OUTPUT ON/OFF and

AUX ON/OFF buttons. After 1 second the model number will appear
on the display for 1 second.

The power supply has been reset.

Foldback delay

0.5 s

Analog programming

Off

Analog programming range

Max

| Current Share Mode | MASTer |

Off

Alarm Output Latches

0 × 87 (or all latches enabled)

Alarms Mask

0 × FF (all enabled)

Interlock

Disabled

Voltage Analog Programming

Off

Voltage APG Scale

10 V

Current Analog Programming

Off

Current APG Scale

10 V

Table 3-9 Power Supply Default Settings