Table 3-1, Select and set from the front panel –3, And table 3-1 – Xantrex Technology XTR 850 Watt User Manual

Page 51

Advertising
background image

Configuring Settings from the Front Panel

975-0200-01-01

3-3

3

Fine adjustment
mode

Pressing the Rotary knob/Enter button to change the mode to fine
adjustment mode provides the ability to manipulate the last significant
digit. Once the exact desired value for the setting has been selected, press
the Rotary knob/Enter button to commit the value to the unit. The coarse
and fine adjustment modes are used for setting the voltage and current set
points, OVP and UVP settings.

Table 3-1 Select and Set from the Front Panel

9 Positions on the Mode
Control Knob

Turning the Rotary Knob lets you…

Pressing the Enter Button lets
you…

VOL (Voltage Programming)

Select the voltage set point in coarse
or fine adjustment modes. See
“Automatic Mode Crossover” on
page 3–11.

Set the value selected and
cycle to the next setting.

CUR (Current Programming)

Select the current set point in coarse
or fine adjustment modes. See
“Constant Current Mode Operation”
on page 3–11
.

Set the value selected and
cycle to the next setting.

FLD (Foldback)

Select Foldback option: CC, CV or
none. See “Setting Foldback Mode”
on page 3–22.

Set the value selected and
cycle to the next setting.

PRT (Protection)

Select the OVP set point (see
page 3–24).
Select the UVP set point (see
page 3–25.)
Select OTP temperature and
Shutdown (see page 3–26.)

Set the value selected and
cycle to the next setting.

SAV (Save User Preset)

Select the user setting memory
location. See “Saving User Setting
Memory Locations” on page 3–28.

Save user setting memory
values.

RCL (Recall User Preset)

Select the user setting memory
location. See “Recalling User
Setting Memory Locations” on
page 3–29
.

Load user setting memory
values into the power supply.

CAP (Current Analog
Programming)

Select the programming source and
select the range.

Set the value selected and
cycle to the next setting.

VAP (Voltage Analog
Programming)

Select the programming source and
select the range.

Set the value selected and
cycle to the next setting.

Advertising