Environmental Specifications (Indoor use)

Operating Temperature Range

0 °C to 50 °C, 100% load

Storage Temperature Range

–20 °C to 70 °C

Operating Humidity Range

30–90% RH (no condensation)

Storage Humidity Range

10–95% RH (no condensation)

Operating Altitude

Up to 6,500 feet (2,000 m)

Installation Category

II (IEC 1010-1)

Pollution Degree

2 (IEC 1010-1)

Mechanical Specifications

XTR 850 Watt (W×H×D)
XTR 1700 Watt (W×H×D)

8.4 Ч 1.7 Ч 19.0 inch (214 Ч 43.6 Ч 483 mm)
16.8 Ч 1.7 Ч 19.0 inch (429 Ч 43.6 Ч 483 mm without rack mount ears)

Weight

XTR 850 Watt: 11 lb (5kg); XTR 1700 Watt: 22 lb (10 kg)

Cooling

Forced air cooling by internal fans

Regulatory Approvals

Safety

CSA 22.2 No. 61010-1 and UL61010-1. Marked with c(UL)us CE (pending) EN61010-1

EMC

Complies with EN55022, Class A, FCC Part 15A for conducted emissions
Complies with EN55022, Class A, FCC Part 15A for radiated emissions
Complies with EN61000-4 series of standards for immunity