PERFORATED CENTER BAND

Drill (6) 3/8" diameter holes equally spaced as shown above for top band clips. Attach clips using 5/16" x 3/

4" bin bolts. Add perforated band sections. Note that these do not attach to the leveling bands but hang down

on the inside of the top inner leveling band.

Measure down 24.1/2"

from first hole in roof

sheet and drill hole for

band clip.

TD-100107

Top Band Clip

(6) Equally spaced

TD-100545

(3) Perforated Band

Figure #48

Roof Sheet