Figure #50 – Grain Systems PNEG-366 User Manual

Page 42

Advertising
background image

Grain Systems, Inc. Assumption, Ill.

42

18' Autoflow

OverFlow Level Switch

TAF-6103

5

30º Roof Panel

Figure #50

3

4

1

2

Key

Part No.

Description

Quantity

Weight

1

TD-100076

Rotary Switch Power-Pak

1

3.50

2

TD-100627

Roof Mount Coupling Weldment

1

2.14

3

TD-100075

Flex-Coupling

1

0.50

4

S-7241

1/8" x 1.1/4" Cotter Pin

2

0.02

5

TAF-6086

3-Vane Paddle

1

0.75

*

TAF-6097

Hardware Package

1

0.98

--

PNEG-300

Rotary Switch Instructions

1

0.04

--

S-275

5/16" - 18 x 3/4" Bin Bolt

6

0.16

--

S-3651

Tube Seal

1

0.74

--

S-396

5/16" - 18 Hex Nut

6

0.06

--

S-7241

1/8" x 1.1/4" Cotter Pin

2

0.02

REV. 11-20-96

* Hardware Package not

shown

-

Included in Hardware

Package

INSTALLATION OF OPTIONAL ROOF-MOUNTED LEVEL SWITCHES

Attach flex-coupling to the power-pak and install roll pin. Apply teflon tape or pipe sealant (not included) to power-

pak pipe threads and thread power-pak into mounting plate coupling. Conduit opening in power-pak should be at right

angles to roof rib or face toward eave.

Caulk underside of mounting plate above and both sides of 2" hole. Bolt to roof panel.