The CKSEL0 Fuse together with the SUT1..0 fuses select the start-up times as shown in
Table 5.

Notes:

1. These options should only be used when not operating close to the maximum fre-

quency of the device, and only if frequency stability at start-up is not important for the
application. These options are not suitable for crystals.

2. These options are intended for use with ceramic resonators and will ensure fre-

quency stability at start-up. They can also be used with crystals when not operating
close to the maximum frequency of the device, and if frequency stability at start-up is
not important for the application.

Table 5. Start-up Times for the Crystal Oscillator Clock Selection

CKSEL0

SUT1..0

Start-up Time from

Power-down and

Power-save

Additional Delay

from Reset

(V

CC

= 5.0V)

Recommended Usage

0

00

258 CK

(1)

4.1 ms

Ceramic resonator, fast
rising power

0

01

258 CK

(1)

65 ms

Ceramic resonator, slowly
rising power

0

10

1K CK

(2)

Ceramic resonator, BOD
enabled

0

11

1K CK

(2)

4.1 ms

Ceramic resonator, fast
rising power

1

00

1K CK

(2)

65 ms

Ceramic resonator, slowly
rising power

1

01

16K CK

Crystal Oscillator, BOD
enabled

1

10

16K CK

4.1 ms

Crystal Oscillator, fast
rising power

1

11

16K CK

65 ms

Crystal Oscillator, slowly
rising power