Dsp loading information, Operating levels, Dsp loading information operating levels – Universal Audio Realtime Rack User Manual

Page 137

Advertising
background image

Realtime Rack Manual

Chapter 6: Using UAD Powered Plug-Ins

137

DSP Loading Information

• Each Realtime Rack hardware unit features four on-board SHARC DSP chips for

processing UAD Powered Plug-Ins.

• Multi-unit Realtime Rack systems use sophisticated load balancing routines. UAD

plug-ins are always allocated as efficiently as possible, which is not necessarily on
the DSP with the lowest resource usage.

• UAD DSP usage is proportional to the system sample rate. Therefore, more plug-

ins can be used simultaneously in a 44.1K session than in a 96K session.

• Bypassing individual components will conserve DSP on some UAD plug-ins. For

example, bypassing the compressor in the EX-1 when only the EQ is in use, and/or
bypassing any of the unused bands of the EX-1 EQ will use less UAD DSP (unless
DSP LoadLock is enabled).

• The UAD DSP resources required by each successive UAD Powered Plug-In in-

stance will slightly decrease.

• A chart showing expected plug-in counts can be found on our website:

uaudio.com/support/uad/compatibility/instance-chart.html

Operating Levels

Except as noted in the table below, the internal operating level of most UAD Powered
Plug-Ins is typically -18 dBFS. 0 dBFS is calibrated to +4 dBu with 18 dB of headroom,
so 0 dBFS is the equivalent of +22 dBu in the analog domain.

UAD Powered Plug-In

Typical Internal Operating Level

0 dBFS Equivalent

Most

–18 dBFS

+22 dBu

Ampex ATR-102
Fairchild Tube Limiter Collection
Teletronix LA-2A Limiter Collection
Studer A800

–12 dBFS

+16 dBu

Manley Massive Passive

–14 dBFS

+18 dBu

Neve 33609 (selectable)

–14 dBFS
–18 dBFS
–22 dBFS

+18 +dBu
+22 +dBu
+26 +dBu

UAD plug-in internal operating levels

Advertising