SEq

NO.

LOCATION ITEM TO

CHECK/SERVICE

PROCEDURE

NOT FULLY MISSION

CAPABLE IF ...

6

Battery Compart-

ment and Cap

Inspect for corrosion, moisture, and corroded or defective

contacts. Inspect for cap damaged or retainer breaks. In-

spect rubber gasket for damag.

Contacts are damaged or corroded. Re-

tainer is broken. Cap or rubber gasket is

damaged.

7

Lenses

Inspect for cleanliness, scratches, chips or cracks.
Clean as required.

Chipped or cracked. Scratches hinder vi-

sion through the equipment.

8

Objective Focus

Ring

Rotate objective focus ring to ensure it is not too tight or too

loose. Range is approximately 3/4 turns.

Ring gets stuck, is too loose, or adversely

affects the user’s ability to properly focus

the objective lens.

9

Eyepiece Focus

Ring

Rotate eyepiece focus ring to ensure the ring is not too tight

or too loose. Range is approximately 2 turns.

Ring gets stuck, is too loose, or

adversely affects the user’s ability to

properly adjust the diopter.

10

Turn-pull Switch

Check for operation (without batteries).

Switch is inoperative.

11

Connector

Inspect for corrosion, moisture, and corroded or defective

contacts. Inspect for cap damaged or retainer breaks.

Contacts are damaged or corroded. Cap

is damaged. Retainer is broken.

12

Mount and Raiser

Inspect for damage or corrosion, for missing parts. Check for

proper operation and attachment security.

Damaged. Missing parts. Clamping de-

vice is inoperative.

13

Remote Control

Unit

Check for damage and missing parts.
Check Velcro tape for wear.

Damaged. Missing parts.

14

Platform Ring

(optional)

Inspect for damage, corrosion, or missing parts. Check for

proper operation. Clean as required.

Damaged. Missing parts.

15

Video Cable

(optional)

Inspect for damage. Inspect the cable connector for corro-

sion, moisture, and corroded or defective contacts. Clean as

required.

Damaged.

OPERATIONAL CHECKS

NOTE:

For a complete operational checking, it is necessary to connect a video monitor to the Zeus.

16

Turn-pull Switch

Install the batteries. Remove the objective lens cap. Point

the equipment at an object. Turn the equipment on. Look

for a thermal image on the display. Look for a flashing bat-

tery icon in the eyepiece viewing area.

No thermal image. Battery icon is flash-

ing (indicates a low battery).

17

Control Board

Ensure the Zeus is responsive to control buttons.

Unresponsive buttons.

18

Remote Control

Turn the equipment to standby. Point the equipment at an

object. Push and hold the remote control button. Look for a

thermal image on the display. Release the button. Turn off

the equipment.

No image.

19

Video Cable

(optional)

Connect an external monitor to the Zeus. Point the equip-

ment on an object. Turn the equipment on. Look for an

image on the monitor. Turn off the Zeus. Disconnect the

monitor.

No image.

20

Boresight

Test boresight as per Part 4.3.3.

POST-CHECK PROCEDURES

Turn off the equipment.
Replace the objective lens cap.
Remove the batteries.
Return the equipment and all accessories to the carrying

case.

4.2 OPERATOR TROUBLESHOOTING

The purpose of troubleshooting is to identify the most frequent equipment malfunctions, probable

causes, and corrective actions required.
Table 4-2 lists the common malfunctions that may be found during the operation or maintenance of

the Zeus. Perform the tests/inspections and corrective actions in the order listed.

TABLE 4-1. CONTINUED