3 maintenance, 1 general – Armasight TAT163WN7ZEUS31 Zeus 640 3-24x75 (30Hz) Thermal Imaging Rifle Scope User Manual
Page 35
35
This table does not list all of the malfunctions that may occur with your device, or all of the tests
and corrective actions that may be necessary. If you experience an equipment malfunction that is
not listed, or is not fixed by the corrective actions listed in the table, please contact Armasight’s Cus-
tomer Service center.
TABLE 4-2. OPERATOR TROUBLESHOOTING
MALFUNCTION
PROBABLE CAUSE/ TEST/INSPECTION
CORRECTIVE ACTION
The Zeus fails to activate.
Batteries are missing or improperly in-
stalled.
Insert batteries or install correctly.
Batteries are dead.
Replace the batteries.
Batteries, surfaces or contacts are dirty or
corroded.
Clean the contact surfaces with a pencil eraser
and/or alcohol and cotton swabs.
Remote control unit is damaged.
Please contact Customer Support.
Remote control batteries are dead.
Replace the batteries as per Part 4.3.4.
The equipment is damaged.
Please contact Customer Support.
The Zeus is not responsive to
control buttons.
The equipment is damaged.
Please contact Customer Support.
Remote control does not work.
Batteries are missing or improperly in-
stalled.
Insert batteries or install correctly.
Batteries are dead.
Replace the batteries.
Batteries surfaces or contacts are dirty or
corroded.
Clean the contact surfaces with a pencil eraser
and/or alcohol and cotton swabs.
Remote control unit is damaged.
Please contact Customer Support.
Poor image quality.
Check objective lens and eyepiece focus.
Refocus.
Check for fogging or dirt on objective lens
and eyepiece.
Clean the lenses as detailed in Part 4.3.2.
The equipment is damaged.
Please contact Customer Support.
No image on an external
monitor.
Video cable is damaged.
Replace the video cable with a new one. Please
contact Customer Support.
The equipment is damaged.
Please contact Customer Support.
Hindered rotation of the bat-
tery cap.
Dirty cap thread.
Clean the thread.
Damaged cap thread.
Replace the cap with a new one. Please contact
Customer Support.
Light is visible around eyecup.
Check eyecup resilience.
If the eyecup is defective, please contact Cus-
tomer Support.
4.3 MAINTENANCE
4.3.1 GENERAL
The Zeus operator maintenance consists of operational tests, inspections for unit serviceability, clean-
ing and mounting procedures, corrective actions (troubleshooting and replacement of a limited num-
ber of parts). Maintenance instructions covered elsewhere in this manual (PMCS, troubleshooting, etc.)
are not repeated in this section.
CAUTION:
The Zeus is a precision electro-optical instrument and must be handled carefully at all times to
prevent damage.
CAUTION:
DO NOT dismantle the equipment.