YSI Professional Plus User Manual

Page 14

Advertising
background image

18

19

lanGuaGe

the Pro Plus can be configured to display all

text in English, Spanish, French, German,

Portuguese, Italian, Norwegian, Simplified

Chinese, traditional Chinese, or Japanese. From

the factory, the instrument includes English,

Spanish, and French language options. the

other language options can be downloaded from

www.ysi.com/support.

once the appropriate language file is in the
instrument, press System

, highlight

Language, and press enter. Highlight the desired

language and press enter to confirm.

radIx poInt

Radix Point allows the user the option to

choose between a comma or a decimal in

numeric displays. For example, 1.00 becomes

1,00 when Use Comma is selected. Highlight

Use Decimal or Use Comma and press enter to

make your selection.

loGGInG

From the System menu, highlight Logging

and press enter to view or change the logging

options. Logging options include Use Site

List, Use Folder List, Continuous Mode, and

Interval.

Use Site List and Use Folder List are optional

ways of filing or ‘tagging’ your logged data

points. If these settings are enabled, you will be

prompted to select a Site and/or Folder to ‘tag’ to the logged data point. See the

File and Site Lists section of this manual for information on creating Site and

Folder Lists.

Check the box for Continuous Mode if you want to log samples continuously

at a specific time interval. to set the length of time between logged samples,

highlight Interval and press enter. Enter the interval as HH:MM:SS. this

interval will display at the top of the screen when you select the Start Logging

option in run mode.

to log one sample at a time, uncheck Continuous Mode. When Continuous

Mode is unchecked, Log One Sample will appear at the top of the run screen.

auto shutoff

Auto Shutoff powers the instrument off after a user specified time period.

Highlight Auto Shutoff and press enter. Using the alpha/numeric entry screen,

enter a value between 0 and 360 minutes. to disable auto shutoff, set the value

to 0 (zero).

BacKlIGht

Backlight can be set to Automatic or Manual.

Automatic turns the backlight on when you

turn the instrument on and when you press any

key. Manual allows you to turn the backlight
on or off with the backlight key

. When

in Automatic mode, the instrument will turn

the backlight off 60 seconds after the last key

press. the instrument will “reset” the 60 second

time period every time a key is pressed. the

lighted keypad will turn off after approximately

20 seconds.

sW VersIon (softWare VersIon)

SW Version shows the instrument’s software version. the instrument’s software

can be updated via www.ysi.com/support. there you will find the new software

files and instructions on how to update the instrument. there is no need to send

the instrument back to the factory for upgrades.

serIal #

Serial # shows the instrument’s serial number and allows you to match it with

the number engraved on the back of the instrument’s case.