Xylem Z6 ZN6 User Manual

Page 21

Advertising
background image

en

21

Pump or auxiliary circuits protection fuses
blown

Replace fuses

Triggering of protection device against dry

running

Check the water level in the tank or well.

If everything is in order, check the
protection device and its connection
cables

Power supply cable is damaged
Electric motor short circuit

Check the components and replace as

necessary

The electric pump starts up but the

thermal protector is immediately triggered
or the fuses blow

Thermal protector or fuses not suited to

the motor current

Motor overload

Check the operating conditions of the
electric pump and reset the protection

Wrong rotation direction

Check the direction of rotation and, if
necessary, exchange two phases in the

electrical panel if the pump is a three-
phase model, or check all the connections
if it is a single-phase model

A phase in the power supply is missing

Check the power supply

The electric pump starts up but, after a

short period of time, the thermal
protector is triggered or the fuses blow.

Power supply voltage not within the

motor’s working limits

Check the operating conditions of the

electric pump

The electric panel is situated in an
excessively heated area or is exposed to
direct sunlight

Protect the panel from heat sources and
from the sun

There are foreign bodies (solid or fibrous

substances) inside the pump, the impellers
are jammed

Extract the electric pump and clean it

The electric pump starts up but, after a

varying period of time, the thermal
protector is triggered.

The pump’s delivery rate is higher than
the limit specified on the rating plate

Partially close the on-off valve located
downstream until the delivery rate returns

to within the specified limits

The temperature of the sucked liquid is
too high

Check the operating conditions of the
electric pump.

Worn motor bearings

Contact our Sales and Service Department

The electric pump starts up but does not
deliver the required flow

Wrong rotation direction (three-phase
version)

Check the direction of rotation and, if
necessary, exchange two phases in the

motor or electrical panel

Pump is not primed because not filled
with water

Repeat the priming procedure

Pump not primed due to tightness failure
in check valve

Check the check valve for perfect tightness

Air in the pipes or pump

Bleed the air

Piping and/or pump clogged

Disassemble and clean

Well water level has dropped too much

Wait for water level to rise or, if possible,

lower the electric pump further

Pump capacity too high for well

Replace the pump with a lower capacity
one

Worn pump

Extract the pump and overhaul it

The system’s general protection cuts in.

Short circuit

Check the electrical system

The system’s differential thermal-magnetic

protection cuts in.

Ground leakage.

Check insulation of the electrical system

components

The pump rotates in the wrong direction
when it is stopped.

Leaks in check valve

Repair or replace the components

The pump starts up too frequently

Leaks in check valve or system

Check and locate leaks. Repair or replace
the components

Ruptured membrane or no air pre-charge

in surge tank

See relevant instructions in surge tank’s

manual

The pump starts up too frequently

Well water level has dropped too much

Wait for water level to rise or, if possible,
lower the electric pump further

Pump capacity too high for well

Replace the pump with a lower capacity
one



9.

Disposal

Information for installation and maintenance personnel

Observe the regulations and codes locally in force regarding sorted waste disposal.