3 device trigger commands, 4 stored settings commands – B&K Precision 4045B - Manual User Manual

Page 81

Advertising
background image

81

4.8.3 Device Trigger Commands

a) *TRG - Trigger command

This command is analogous to the IEEE 488.1 Group

Execute Trigger interface message, and has the same

effect. It is used to trigger the device to output a wave, and

is accepted only when the trigger mode is set to Trigger,

Gate or Burst, and the trigger source is set to BUS.

Type: Common Command

Syntax: *TRG

4.8.4 Stored Settings Commands

*RCL - Recall instrument state

This command is used to restore the state of the device to

that stored in the specified memory location.

Arguments

Type <NRf>

Range 0 to 19 (4045B). Non integer values are

rounded before execution

Type: Common Command

Syntax: *RCL<ws><NRf>

Example: *RCL 0 (Recall default state)

*RCL 9

Advertising