Q.V.P. ES5 Veneering & Clamping at the same time User Manual

Quality vakuum products, inc, Es5 super pro set-up diagram

Advertising
background image

ES5 SUPER PRO SET-UP DIAGRAM

SIMULTANEOUS VENEERING & KLAMPING

The Electric Pump is always running when doing
VAKuum Klamping; therefore, put the switch on the
Electric Controller to “VAK Klamp.” NEVER do VAKuum
Klamping
with the switch on “VAK Bag.”

When you are not using the pump for Klamping keep the
foot pedal off or remove the Klamping set-up and attach
the hose with the check valve directly onto the filter.

Pressing

on its top side creates vacuum to the

VAK Klamp(s) and the VAK Bag(s). Pressing the pedal
on its bottom side shuts off the vacuum from the pedal to
the klamp and allows air to bleed back to the klamp and
release the piece. The check valve prevents air from
bleeding back into the bag.

the pedal

Vacuum

Gauge

Tee

Tee

VAKuum

Jig

Check

Valve

(Red end

towards bag)

Tee

3/17/98 - ES5 SuperPro K&V.CDR (REV.1)

Quality VAKuum Products, Inc.

Or visit our site at

www.qualityvak.com

CALL 1-800-547-5484 TODAY!

Klamping Set-Up

1/2 I.D.

3/8 I.D.

1/2 I.D.

VAKuum

Bag

Pneumatic

Pedal

Filter

Electric Pump

Electric

Controller

X

Remove orange plastic plug and screw in filter assembly.

74 Apsley St. - Hudson, MA 01749
Tel: 978-562-4680 - Fax: 978-562-4681