2 router operation, Outer, Peration – Castle TSM-21 Diagnostic Manual User Manual

Page 12

Advertising
background image

Castle Inc

TSM-21 Diagnostic Manual v2

Page 12 of 63

4.2 Router Operation

Page Procedure

Router doesn’t cut pocket…Machine Clamps and Drills, but Clamp DOES NOT release:

□ Check Router Feed Rate may be turned all the way down……... 31-32

21.32

□ Check Router Solenoid for function or blockage…………………. 30-31

21.31

□ Unclog Router Solenoid…………………………………………….. 29-30

21.30

□ Router Motor Operation…………………………………………….. 24-26

21.20

□ Check Router SQE Valve …………………………………………..
(or Solenoid exhaust port ) for leakage

43-44

21.61

□ Check Drill SQE Valve……………………………………………….
(or Solenoid exhaust port ) for leakage

43-44

21.61

Router

doesn’t cut pocket… Machine Clamps, Drills and releases:

□ Check Router Stop Switch for function or adjustment…………… 27-29

21.22

Router

comes up and STAYS UP as soon as air is attached…..with Machine power OFF:

□ Check Router Solenoid for function or blockage…………………. 30-31

21.31

□ Unclog Router Solenoid…………………………………………….. 29-30

21.30

Router

cuts pocket and STAYS UP, Drill doesn’t come out and Clamp doesn’t release:

□ Check Router Stop Switch for function or adjustment…………… 27-29

21.22

Router

cuts pocket, Drill doesn’t come out and Clamp doesn’t release:

□ Check Drill Solenoid for function or blockage…………………….. 38-39

21.50

Router

advances too aggressively:

□ Adjust internal Air Pressure………………………………………… 51-52

21.90

□ Adjust the Router Feed Rate……………………………………….. 31-32

21.32

Advertising