2.

Un-plug or turn off both routers

3.

Place two boards on opposite sides of the slot on the Table Top, press them against the
Safety Buttons, and depress the Foot Pedal.

4.

At the rear door, manually simulate the Router and Drill strokes by first pulling, then
pushing the yellow Motor Carriage.

5.

Make sure air escapes first from the Router Solenoid and then from the Drill Solenoid be-
fore the manual cycle is complete.

6.

Reconnect the “Air Out” lines to the Router and Drill Solenoids. See Fig 22.

7.

Disconnect the “Air Out” lines at the Drive Cylinder SQE valves. See Fig 23.

8.

Repeat Steps 3 and 4.

9.

The air lines should exhaust air as you manually cycle. Make sure air escapes first from
the black Router Solenoid line and then from the translucent Drill Solenoid line before the
manual cycle is complete.

10.

This should clear any blockage from the air lines and Drive Cylinder SQEs

11.

Reconnect the air lines to the Drive Cylinder as shown Fig 23.

Drive Cylinder

Router SQE Valve

Drill Solenoid line

Drill SQE Valve

Router Solenoid line

Fig 23

12.

Turn the routers back on and cut a test pocket.