3 definitions, Definitions – Castle TSM-21 Diagnostic Manual User Manual

Page 8

Advertising
background image

Castle Inc

TSM-21 Diagnostic Manual v2

Page 8 of 63

3 Definitions

Term

Definition

Air Pressure
Regulator

Used to set the main operational speed of the machine. Factory set at
approximately 75 PSI. / approximately 6 full clockwise turns from stop.

Bar Spring

Provides pressure to return the Motor Carriage to neutral after the
Pilot Drill stroke.

Continuity Testing

“Visual Indicator” type testers use batteries and a light
bulb.

“Audible Indicator” type testers use batteries and a
beeper or buzzer.

Normally OPEN (NO) switches read no continuity at rest, IE; NO light
or sound from tester.

Normally CLOSED (NC) switches read continuity at rest, IE: light or
sound from tester.

Drill Motor

Porter Cable 7301 Trimmer motor used to drill the Pilot Hole.

Drive Cylinder

A double acting air cylinder which moves the Motor Carriage
backwards for the Pocket Router stroke and forwards for the Pilot Drill
stroke.

Pilot Hole

The Screw hole drilled by the Drill motor.

Pilot Valve

Provides full pressure to the Clamp cylinder. It is controlled by the
Clamp Solenoid.

Note:

Used up to machine SN: 61076 only

Pocket

The pocket cut in the material by the Pocket Router motor.

Router Motor

Porter Cable 6902 used to cut the Pocket.

Router Feed Rate
Valve

Controls the speed at which the Pocket Router moves through the
material when cutting the Pocket.

Note:

Should be adjusted AFTER the main operational speed of
the machine has been set with the Air Pressure Regulator.

Advertising