4.3 Drill Operation

Page Procedure

Drill

DOES NOT come out, Machine Routs, Clamp DOES NOT release:

□ Check Drill Solenoid for function or blockage…………………….. 40-41

21.51

□ Unclog Drill Solenoid………………………………………………… 38-39

21.50

Drill

comes out and stays out as soon as air is attached…with Machine power OFF:

Machine DOES NOT finish cycle when carriage is pushed forward by hand:

□ Check Drill Motor is On……………………………………………… 33-34

21.40

□ Check Drill Stop Switch for function or adjustment………………. 37-38

21.43

Drill

comes out and stops, Router cuts pocket and Clamp DOES NOT release:

Machine DOES finish cycle when carriage is pushed forward by hand:

□ Adjust Air pressure, may be too low……………………………….. 51-52

21.90

□ Check Drill Solenoid for function or blockage …………………….. 40-41

21.51

□ Unclog Drill Solenoid………………………………………………… 28-39

21.50

□ Check Router SQE Valve……………………………………………
(or Solenoid exhaust port ) for leakage

43-44

21.61

□ Check Drill SQE Valve……………………………………………….
(or Solenoid exhaust port ) for leakage

43-44

21.61

Drill

bit not completing pilot hole into Pocket:

□ Adjust air pressure, Machine cycling too slowly………………….. 51-52

21.90

□ Bit mounted too deep into collet……………………………………. 34-35

21.41

Drill

bit separating from the shank:

□ Adjust air pressure, Machine cycling too slowly………………….. 51-52

21.90

□ Bit mounted too deep into collet……………………………………. 34-35

21.41