28 attaching air supply 21.92, Ttaching, Upply – Castle TSM-21 Diagnostic Manual User Manual

Page 54

Advertising
background image

Castle Inc

TSM-21 Diagnostic Manual v2

Page 54 of 63

9.

Reassemble the solenoids in a stack and tighten the hex nuts and lock washers. Do not
over tighten the hex nuts.

10.

Reinstall the Control Box using the carriage bolts.

11.

Reconnect air and then power to the machine.

5.28 Attaching

Air

Supply

21.92

An air supply with a MINIMUM of 80 PSI must be provided for proper operation of the TSM-21

Pocket Machine.

1.

From the operator’s position the air inlet is the 1/4” NPT fitting located on the left side.

2.

Use proper thread sealant and install desired attachment method.

3.

CASTLE recommends the use of a secondary filter method directly in line with the supply
at the machine.

4.

Do not use lubricants or connect a lubricator to the machine.

Warning:

Do not turn the machine on without air attached.

Advertising