7 router motor operation 21.20, 1 removing / installing the router motor, Outer – Castle TSM-21 Diagnostic Manual User Manual

Page 24: Otor, Peration

Advertising
background image

Castle Inc

TSM-21 Diagnostic Manual v2

Page 24 of 63

7.

Apply Teflon tape to the brass fitting still attached to the regulator.

8.

Tighten the Pilot Valve onto the brass fitting.

9.

Reattach the three plastic fittings and black hoses to the new Pilot Valve.

10.

Put the plastic nut back on the regulator and tighten.

11.

Re-install the Control Box using the carriage bolts.

12.

Reconnect air and then power to the machine.

5.7 Router

Motor

Operation

21.20

The Router Motor has its own power switch located on the motor body. This switch should be in

the ON position as motor operation is controlled by the main Power Switch on the machine.

Warning:

Do not run the motor for more than two hours at a time. The motor requires a ½ hour

cool down period after each two hour period.

5.7.1 REMOVING / INSTALLING THE ROUTER MOTOR:

1.

Disconnect power and air from the machine.

2.

Open the rear door and locate the Drill Motor. Just to the right is a T-Knob that tightens
a large U-Bolt holding the Router Motor in place. See Fig 8.