 If the cycle stalls with the drill extended or if the cycle skips over the drill stroke

entirely, check the Drill Stop Switch: Procedure 21.43

 If the complete cycle takes significantly longer than two seconds, check the Air

Supply, the Pressure Regulator, and the Router Feed Rate: Procedures 21.92, 21.90

and 21.32

 If the Dry Cycle is successful, but a regular cycle fails when routing actual pockets

and drilling holes, check the Tooling, the Motor Operation, and the Drive Cylinder:

Procedures 21.83, 21.20 and 21.60

Note:

For comprehensive diagnostic descriptions and procedures refer to Section IV.

After testing is complete, turn the MAIN Power Switch OFF and switch both motors back ON or