16 drill stop switch (nc) 21.43, 1 testing steps, Rill – Castle TSM-21 Diagnostic Manual User Manual

Page 37: Witch

Advertising
background image

Castle Inc

TSM-21 Diagnostic Manual v2

Page 37 of 63

6.

Push the carriage forward by hand. The carriage should “spring” back when released.

7.

Reinstall the Control Box and reconnect air and then power to the machine.

5.16 Drill

Stop

Switch

(NC)

21.43

The Drill Stop Switch consists of a magnetic reed switch (with wires) and a magnet (no wires).

The switch is Normally CLOSED (NC) and OPENS at the end of the Pilot Hole cycle when the

Motor Carriage breaks the magnetic field. The switch then signals both the Drill solenoid and

Clamp solenoid to stop airflow, which allows the Drill to retract and Clamp to release.

If the Drill Stop Switch fails, or the magnetic field weakens or becomes misaligned, the machine

will not sense the end of the drill cycle. The drill may stay forward in the Pilot Hole causing the

cycle to stall or the clamp may extend but immediately release.

5.16.1

TESTING STEPS:

1.

Disconnect power and air from the machine.

2.

The Drill Stop Switch and magnet are located inside the machine on the back side of the
Face Plate, slightly to the left of the Pilot Drill Hole. See Fig 18.

Drill Stop Switch

Motor Carriage

Drill Stop Magnet

Fig 18