12 router feed rate adjustment 21.32, Outer, Djustment – Castle TSM-21 Diagnostic Manual User Manual

Page 31

Advertising
background image

Castle Inc

TSM-21 Diagnostic Manual v2

Page 31 of 63

Pilot Valve, up to

sn:61076

Clamp Exhaust

Clamp Solenoid

Router Solenoid

Fig 13

3.

Attach the air supply to the machine and see if the drill now extends instead of the router.

4.

If it does, the Router Solenoid has stuck open.

5.

Swap the air lines back again.

6.

Perform procedure 21.30 “Unclogging the Router Solenoid”.

5.12 Router

Feed

Rate

Adjustment

21.32

The Router Feed Rate is adjustable to accommodate varying materials and/or bit types. If the

Router Feed Rate is too fast, stock slippage, poor pocket quality, or dulled tooling may result. If

the Router Feed Rate is too slow pocket burning and premature wear of the tooling may result.

As a rule of thumb – the harder the material, the slower the feed rate of the Router.

Note:

If the Pressure Regulator has been adjusted, readjust the Router Feed Rate (if
necessary) AFTER the Pressure Regulator setting has been finalized.

Air IN lines

Air OUT lines

Drill Solenoid

Router Feed Rate Knob

Regulator Knob

Advertising