Installation – Fulton Vertical Coil (FT-C_S) Thermal Fluid (hot oil) Heater User Manual

Page 31

Advertising
background image

Questions? Call (315) 298-5121, or visit us online at www.fulton.com

SECTION 2

FTCS-IOM-2013-1114

INSTALLATION

2-25

(50.8)

2

C

L

J

E

F

D

1/2C

(76)

3

A

N2 REGULATOR

R

R

CONNECTION

TEST

MANUAL

LEVEL

LIQUID

DRAIN & LIQUID LEVEL

(13)

1/2

DRAIN

N

G

H

OUTLET

INLET

COUPLING

SWITCH

LIQUID LEVEL

BUFFER

THERMAL

DEAERATOR

M

B

B

K

EXPANSION TANK

(13)

1/2

(TYP.)

VENT

P

VALVE CONN.

SAFETY RELIEF

Model

A

B

C

D

E

F

G

H

J

K

L

M

N

P

CAP

Dry

Wt.

Max

Full

Wt.

FT-

0200-L

20

(510)

12

3/4

(325)

54

(1370)

60

5/8

(1540)

34

(865)

26

5/8

(676)

16

11/16

(424)

12

(305)

4

1/2

(115)

4

1/4

(108)

15

(380)

12

15/16

(329)

3/4

(20)

3/4

(20)

52

(200)

636

(289)

1314

(596)

FT-

0500-L

26

(660)

16

(405)

74

(1880)

66

5/8

(1692)

37

(940)

29

5/8

(752)

19

3/4

(502)

14

(355)

6 (150)

11

1/2

(290)

18

(460)

14

15/16

(379)

3/4

(20)

3/4

(20)

132

(500)

970

(440)

2450

(1111)

FT-

1000-L

36

(915)

20

(510)

76

(1930)

87

5/8

(2226)

49

(1245)

38

5/8

(981)

22

1/4

(565)

15

(380)

7

11/16

(202)

14 (355)

24

(610)

14

15/16

(379)

1

(25)

1

(25)

264

(1000)

1350

(612)

4380

(1987)

FT-

1500-L

36

(915)

20

(510)

106

(2690)

87

(2210)

49

(1245)

38

5/8

(981)

24

3/4

(629)

17

1/2

(445)

8 (203)

14 (355)

24

(610)

14

15/16

(379)

1

(25)

1

1/4

(32)

397

(1500)

1710

(776)

5875

(2667)

FT-

2000-L

42

(1070)

22

(560)

106

(2690)

107

5/8

(2734)

62

1/2

(1590)

45

1/8

(1146)

31

3/16

(792)

24

(610)

8

1/2

(216)

15

1/2

(394)

28

(710)

14

15/16

(379)

1

(25)

1

1/2

(38)

528

(2000)

2550

(1134)

8230

(3733)

FT-

3000-L

42

(1070)

26

(660)

140

(3556)

115

1/8

(2924)

70

(1778)

45

1/8

(1146)

33

3/16

(843)

24

(610)

9

15/16

(252)

15

1/2

(394)

28

(710)

18

15/16

(481)

1

(25)

1

1/2

(38)

793

(3000)

3200

(1451)

11,610

(5265)

FT-

5000-L

60

(1524)

26

(660)

130

3/8

(3312)

132

1/8

(3356)

77

1/2

(1969)

54

5/8

(1387)

32

3/16

(818)

24

(610)

9

3/8

(238)

20

5/8

(524)

37

(940)

18

15/16

(481)

1

(25)

1

1/2

(38)

1321

(5000)

5300

(1637)

17,370

(7895)

Inlet and outlet dimensions vary with installation. All dimensions are approximate. Specifi cations are subject to change without notice. Dimensions

are in inches (mm). Capacities are in gallons (liters). Weights are in pounds (kg).

FIGURE 14 -

COMBINATION/EXPANSION/DEAERATOR THERMAL BUFFER TANK