Ransburg, Dynaflow, Programer's manual - introduction – Ransburg DynaFlow Programmers Manual User Manual

Page 34

Advertising
background image

Command T

ype

(hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

15) <MH><MH> = Master Channel hardware word (see below). 16) <SH><SH> = Slave Channel hardware word (see below). 17) <GI><GI> = Gun Input word (see below). 18) <GO> = Gun Output byte (see below). 19) <RG> = RIO Gun Input byte (see below). 20) <FI><FI> = Forced Gun Input word (see below). 21) <FO> = Forced gun Output byte (see below). 22) <RS> = RIO System Input byte (see below). Hardware W

ord:

Bit 0 = DR1 1:1 Bit 1 = DR1 1:2 Bit 2 = DR1 1:3 Bit 3 = DR1 1:4 Bit 4 = DR1 1:6 Bit 5 = DR1 1:8 Bit 6 = DR1 1:10 Bit 7 = MVR #2 Bit 8 = MVR #3 Bit 9 = MVR #4 Bit 10 = Other

Gun Input & Forced Gun Input words: Bit 0 =

Trigger

Bit 1 = Run Bit 2 = Halt Bit 3 = Clean Bit 4 = Enable Bit 5 =

Total Reset

Bit 6 =

Total Hold

Bit 7 =

Transparent Mode

Bit 8 =

Analog Hold

Bit 9 = Gun Mask Bit 10 = Load Bit

1

1

=

External

Gun

Fault

RIO Gun Input byte: Bit 0 =

Trigger

Bit 1 = Run Bit 2 =

Transparent Mode

Bit 3 =

Total Hold

Bit 4 = Halt Bit 5 =

Total Reset

Bit 6 = Clean Bit 7 = Load

30

DynaFlow

Programer's Manual - Introduction

Ransburg

LN-9406-00.3

Advertising